System Messages of the MMI and Solutions 2-21 mounter . The tray feeder type in the chip mounter is incorrect. [Solution] Check the communication cable. Check the tray feeder type and other settings in the chip mounter .…

100%1 / 149
Samsung Component Placer CP-45F(V)/FS Reference Manual
2-20
[Problem]
The power of tray feeder is off
Communication line to the tray feeder is not normal.
[Solution]
Check the power of tray feeder.
Check the communication cable between the tray feeder and the chip mounter.
$5501 Tray feeder is in error.
[Problem]
The tray feeder is in error.
[Solution]
Remove the cause of error from the tray feeder and restart.
$5502 Tray feeder is not ready.
[Problem]
The tray feeder is not ready
[Solution]
Prepare the tray feeder for operation.
$5503 Error in the tray feeder communication command.
[Problem]
An error occurred during the communication between the tray feeder and the chip
mounter.
The tray feeder type in the chip mounter is incorrect.
[Solution]
Check the communication cable.
Check the tray feeder type and other settings in the chip mounter.
$5504 Error in the tray feeder communication data.
[Problem]
An error occurred during the communication between the tray feeder and the chip
System Messages of the MMI and Solutions
2-21
mounter.
The tray feeder type in the chip mounter is incorrect.
[Solution]
Check the communication cable.
Check the tray feeder type and other settings in the chip mounter.
$5505 No palette in the tray feeder.
[Problem]
There is no specified palette in the tray feeder
[Solution]
Supply the specified palette.
$5506 Time out error in the tray feeder.
[Problem]
There is no response from the tray feeder within the specified time.
[Solution]
Check the tray feeder communication cable.
Check the tray feeder related setting in the chip mounter.
$5507 TRAY_NO_DATA_ERROR.
$5508 TRAY_INVALID_PR_ERROR
$5509 TRAY_SENDING_ERROR
$550a TRAY_INVALID_RES_ERROR
$550b TRAY_INVALID_CMD_ERROR
$55ff TRAY_NOT_DEFINED
Samsung Component Placer CP-45F(V)/FS Reference Manual
2-22
$5800 Vacuum check error in the component $P supplied from the feeder $F.
[Problem]
An error occurs when the supplied component is checked for vacuum.
There is no supplied component
The vacuum level is set incorrectly
The vacuum sensor is abnormal
[Solution]
Supply components.
Check the vacuum level of the nozzle in the System device.
Check the vacuum and if there is any abnormality, replace it.
$5801 Vision check error in the component $P supplied from the feeder $F.
[Problem]
An error occurs when the supplied component is vision checked.
There is no component
[Solution]
Supply components.
$6001 Can't open the mirror.
[Problem]
Can't open the mirror
[Solution]
Please contact our C/S.
$6002 Can't open the ANC.
[Problem]
The ANC can't be opened due to mechanical interference
The position of the ANC sensor is incorrect
[Solution]
Check if there is any mechanical interference.