cp45ref.pdf - 第69页
System Messages of the MMI and Solutions 2-15 $3402 Can't lower the work stopper . [Problem] The mounting stopper can't be lowered due to mechanical interference The position of the mounting stopper is incorrec…

Samsung Component Placer CP-45F(V)/FS Reference Manual
2-14
$3201 Can't move the PCB in the waiting sensor area.
$3202 Can't move the PCB in the mounting sensor area.
$3203 Can't move the PCB in the output sensor area.
$3301 Can't raise the wait stopper.
[Problem]
The wait stopper can't be raised due to mechanical interference
The position of the wait stopper is incorrect.
[Solution]
Remove the mechanical interference.
Adjust the position of the sensor after checking whether it operates or not.
$3302 Can't lower the wait stopper.
[Problem]
The wait stopper can't be lowered due to mechanical interference
The position of the wait stopper is incorrect.
[Solution]
Remove the mechanical interference.
Check if the sensor operates properly and adjust its position
$3401 Can't raise the work stopper.
[Problem]
The mounting stopper can't be raised due to mechanical interference
The position of the mounting stopper is incorrect
[Solution]
Remove the mechanical interference.
Check if the sensor operates properly and adjust its position

System Messages of the MMI and Solutions
2-15
$3402 Can't lower the work stopper.
[Problem]
The mounting stopper can't be lowered due to mechanical interference
The position of the mounting stopper is incorrect
[Solution]
Remove the mechanical interference.
Check if the sensor operates properly and adjust its position.
$3501 Can't raise the out stopper.
$3502 Can't lower the out stopper.
$3600 AREA_PCB_OVER_MAXIMUM_WARNING.
$3601 MOUNTING_OVER_MAXIMUM_WARNING.
$3700 SMEMA_SIGNAL_TIMEOUT_ERROR.
$3701 Time out error occurred on the conveyor during operation.
[Problem]
Time out occurred during the transfer of PCB on the conveyor.
[Solution]
Correct the problem and restart.
$3fff CONV_NOT_DEFINED
[Problem]
The conveyor related setting is not correct.
[Solution]
Please contact our C/S.

Samsung Component Placer CP-45F(V)/FS Reference Manual
2-16
$4000 Components that can't be operated together exist in a cycle.
[Problem]
The components that can't be operated together exist in a cycle
[Solution]
Divide one cycle into two and operate.
$4001 Error occurred during a manual operation.
[Problem]
An error occurred during a manual operation.
[Solution]
Please contact our C/S.
$4002 Undefined operation mode is used.
[Problem]
An undefined operation mode is used.
[Solution]
Set the operation mode ( Normal/Dry …) again.
Please contact our C/S.
$4004 Method of deciding bad mark position is invalid.
[Problem]
S/W error
[Solution]
Please contact our C/S.
$4005 Undefined door method.
[Problem]
The door type is set incorrectly
[Solution]
Set the door again in the system setup.