cp45ref.pdf - 第59页
System Messages of the MMI and Solutions 2-5 $1001 + H/W Limit is sensed at the $A axis. [Problem] The H/W limit sensor in + direction is sensed at the specified axis. [Solution] Move each axis to a position that can&apo…

Samsung Component Placer CP-45F(V)/FS Reference Manual
2-4
When an axis is to move, other axes are not in safe positions.
[Solution]
Please contact our C/S.
$0803 During a manual operation, the %d axis interferes when the %d side is to be
moved.
[Problem]
When an axis is to move, other axes are not in safe positions.
[Solution]
Please contact our C/S.
$0804 During a manual operation, the %d axis interferes when the %d side or the %d axis
is to be moved.
[Problem]
When an axis is to move, other axes are not in safe positions.
[Solution]
Please contact C/S.
$1000 - H/W Limit is sensed at the $A axis.
[Problem]
The H/W sensor in - direction is sensed at the specified axis.
[Solution]
Move each axis to a position that can't be sensed by the H/W limit sensor.
Reset the S/W limit of the specified axis.

System Messages of the MMI and Solutions
2-5
$1001 + H/W Limit is sensed at the $A axis.
[Problem]
The H/W limit sensor in + direction is sensed at the specified axis.
[Solution]
Move each axis to a position that can't be sensed by the H/W limit sensor.
Reset the S/W limit of the specified axis.
$1002 Alarm is sensed at the $A axis.
[Problem]
In the case of an axis, excessive pressing can cause this.
A motor error occurred at the specified axis.
[Solution]
Check the height during the corresponding operation at the Z axis.
If it is due to other reasons or if it happens repeatedly, please contact our C/S.
$1003 $A axis did not stop within the set time.
[Problem]
The specified axis did not stop within the set time after it moved.
Bad wiring related to the axis.
Bad board related to the axis
[Solution]
Check if there is any mechanical interference blocking the movement of the specified axis.
Check the wiring.
Replace the axis board.

Samsung Component Placer CP-45F(V)/FS Reference Manual
2-6
$1004 Error was detected at the $A axis.
[Problem]
An error occurred at the specified axis.
[Solution]
Check if there is any mechanical interference at the specified axis.
Check the specified axis and related wiring.
Replace the board of the specified axis.
$2000 Encoder error was detected at the conveyor width control axis.
[Problem]
An error occurred when the conveyor related encoder was checked.
[Solution]
Check the wiring related to conveyor width control.
Replace the related board.
$2001 Can 't raise the BUT.
[Problem]
The BUT (Back Up Table) does not move when it is to be lifted.
The up sensor is not sensed when the BUT (Back Up Table) is to be lifted.
The down sensor is sensed when the BUT (Back Up Table) is to be lifted.
[Solution]
Check if the air pressure supplied to the equipment is normal.
Check if the conveyor I/O board is normal.
Check the operation of the BUT up sensor.
Check the position of the BUT up sensor.
Check the operation of the BUT down sensor.
Check the position of the BUT down sensor.