cp45ref.pdf - 第67页
System Messages of the MMI and Solutions 2-13 The sensitivity of the mounting sen sor is adjusted incorrectly The time out value is too low [Solution] Remove the dropped PCB and start again. Remove the mechanical interfe…

Samsung Component Placer CP-45F(V)/FS Reference Manual
2-12
A PCB is in the mounting sensor area when the operation is to start.
[Solution]
If there is one PCB in the conveyor mounting terminal and if it is all right to start
operation, press START.
If there is more than one PCB in the conveyor mounting terminal, remove them.
$3023 PCB is in the output buffer.
[Problem]
A PCB is in the output sensor area when the operation is to start
[Solution]
If there is one PCB in the conveyor output terminal and if it is all right to start operation,
press START.
If there is more than one PCB in the conveyor output terminal, remove them.
$3101 PCB has not arrived in the waiting sensor area.
[Problem]
The PCB is dropped during transfer
The PCB is blocked due to mechanical interference during transfer
The sensitivity of the waiting sensor is adjusted incorrectly
The time out value is too low.
[Solution]
Remove the dropped PCB and start again.
Remove the mechanical interference.
Adjust the sensitivity of the waiting sensor again.
Adjust the time out value. (Factory setting)
$3102 PCB has not arrived in the mounting sensor area.
[Problem]
The PCB is dropped during transfer
The PCB is blocked due to mechanical interference during transfer

System Messages of the MMI and Solutions
2-13
The sensitivity of the mounting sensor is adjusted incorrectly
The time out value is too low
[Solution]
Remove the dropped PCB and start again.
Remove the mechanical interference.
Adjust the sensitivity of the mounting sensor again.
Adjust the time out value. (Factory setting)
$3103 PCB has not arrived in the output sensor area.
[Problem]
The PCB is dropped during transfer
The PCB is blocked due to mechanical interference during transfer
The sensitivity of the take out sensor is adjusted incorrectly
The time out value is too low
[Solution]
Remove the dropped PCB and start again.
Remove the mechanical interference.
Adjust the sensitivity of the output sensor again.
Adjust the time out value. (Factory setting)
$3104 Error occurred during PCB output
[Problem]
The PCB is not taken out completely
The PCB is blocked due to mechanical interference during transfer
The sensitivity of the output sensor is adjusted incorrectly
When the time out value is too low
[Solution]
Find the cause and take corrective measures.
Remove the mechanical interference.
Adjust the sensitivity of the output sensor again.
Adjust the time out value. (Factory setting)

Samsung Component Placer CP-45F(V)/FS Reference Manual
2-14
$3201 Can't move the PCB in the waiting sensor area.
$3202 Can't move the PCB in the mounting sensor area.
$3203 Can't move the PCB in the output sensor area.
$3301 Can't raise the wait stopper.
[Problem]
The wait stopper can't be raised due to mechanical interference
The position of the wait stopper is incorrect.
[Solution]
Remove the mechanical interference.
Adjust the position of the sensor after checking whether it operates or not.
$3302 Can't lower the wait stopper.
[Problem]
The wait stopper can't be lowered due to mechanical interference
The position of the wait stopper is incorrect.
[Solution]
Remove the mechanical interference.
Check if the sensor operates properly and adjust its position
$3401 Can't raise the work stopper.
[Problem]
The mounting stopper can't be raised due to mechanical interference
The position of the mounting stopper is incorrect
[Solution]
Remove the mechanical interference.
Check if the sensor operates properly and adjust its position