System Messages of the MMI and Solutions 2-3 [Solution] Close the front door . Check the sensor or the wiring area. $0021 Rear door is open. [Problem] The rear door is open. The rear door sensor or the wiring area is wro…

Samsung Component Placer CP-45F(V)/FS Reference Manual
2-2
[Solution]
Press the I of the main start switch.
$0007 Can't turn on the I/O power switch.
[Problem]
The ready relay is on, but the power is not turned on within the set time.
[Solution]
Check the wiring of the I/O area of the main start switch.
Check the wiring of the related area of ready relay.
$0010 Front feeder unlock sensor is sensed.
[Problem]
There is a loose feeder in the front feeder station.
The loose sensor is sensed in the front feeder station due to other reasons.
[Solution]
Check if there is any loose feeder in the front station and take corrective measures.
Remove the contamination sensed by the unlock sensor.
$0011 Rear feeder unlock sensor is sensed.
[Problem]
There is a loose feeder in the rear feeder station.
The unlock sensor is sensed due to other reasons.
[Solution]
Check if there are any loose feeders in the rear station and take corrective measures.
Remove the contamination sensed by the unlock sensor.
$0020 Front door is open.
[Problem]
The front door is open.
The front door sensor or the wiring area is wrong.

System Messages of the MMI and Solutions
2-3
[Solution]
Close the front door.
Check the sensor or the wiring area.
$0021 Rear door is open.
[Problem]
The rear door is open.
The rear door sensor or the wiring area is wrong.
[Solution]
Close the rear door.
Check the sensor or the wiring area.
$0100 Vme Module Ver % d is executed.
[Problem]
It is only for checking when the VME Program is started, it is a regular operation.
[Solution]
$0800 Other axes interfere when the $A axis is to be moved.
[Problem]
Other axes are not in safe positions when an axis is to move.
[Solution]
Please contact our C/S.
$0801 AXIS_SAFE_POS_MOVE_ERROR.
[Problem]
An error occurs when a certain axis is to be moved to a safe position.
[Solution]
Please contact our C/S.
$0802 Other axes interfere when the $A axis is to be moved.
[Problem]

Samsung Component Placer CP-45F(V)/FS Reference Manual
2-4
When an axis is to move, other axes are not in safe positions.
[Solution]
Please contact our C/S.
$0803 During a manual operation, the %d axis interferes when the %d side is to be
moved.
[Problem]
When an axis is to move, other axes are not in safe positions.
[Solution]
Please contact our C/S.
$0804 During a manual operation, the %d axis interferes when the %d side or the %d axis
is to be moved.
[Problem]
When an axis is to move, other axes are not in safe positions.
[Solution]
Please contact C/S.
$1000 - H/W Limit is sensed at the $A axis.
[Problem]
The H/W sensor in - direction is sensed at the specified axis.
[Solution]
Move each axis to a position that can't be sensed by the H/W limit sensor.
Reset the S/W limit of the specified axis.