cp45ref.pdf - 第40页

Samsung Component Placer CP-45F(V)/FS Refer ence Manual 1-14 tight fastening can be maintained. At this time, take precautions so that the O-ring for packing located inside the blow chamber doesn't get dislocated. 1…

100%1 / 149
Preventive Maintenance
1-13
Place a soft cloth beneath the spindle and pour a small amount of alcohol from the top
of the spindle.
Using an air gun, completely blow out any residue or alcohol that may be inside the
spindle.
Figure 1-5. Remove the contamination in the spline shaft
1.2.1.7. Air Section
Inspection
Check to see if there is any abnormal air leak from the air distributor or the fitting
joint area of the solenoid valve.
Check to see if there is any air leak from the blow chamber attached to the solenoid
valve.
Figure 1-6. Vacuum Generator
Solution
If there is air leak from the fitting joint area, tighten it firmly enough but not enough
to break it. If the fitting is damaged, please contact our C/S center for A/S.
When the blow chamber is not tightened enough, air leak can occur. Tighten it so that
Caution
Make sure the alcohol does not spill out from the spindle
when pouring the alcohol into the spindle and make sure to
block the bottom of the spindle with a piece of cloth.
O-ring
Air Distributor
Joint
Sp
lin
e
S
h
a
f
t
Blow Chamber
Fitting
Housing
Samsung Component Placer CP-45F(V)/FS Reference Manual
1-14
tight fastening can be maintained. At this time, take precautions so that the O-ring for
packing located inside the blow chamber doesn't get dislocated.
1.2.2. X-Y Frame Section
1.2.2.1. X-axis L/M Guide Rail
Inspection
Check the rail for discoloration or dust.
Check the lubricants on the rails. Insufficient lubricants on the rails could cause
unusual noise during operation of the machine.
X-axis L/M Guide Rail & Bloc
Figure 1-7. X-axis L/M Guide Rail & Block
Solution
Caution
It may shorten the average life span of a machine if grease
not specified by our company is applied on the machine. Use
the grease specified by our company.
Preventive Maintenance
1-15
Clean any contamination or dust on the rail, and apply grease if necessary.
1.2.2.2. Y-axis L/M Guide Rail
Inspection
Check the rail for discoloration or dust.
Check the lubricants on the rails. Insufficient lubricants on the rails could cause
unusual noise during operation of the machine.
Figure 1-8. Y-axis L/M Guide
Solution
L/M Guide Block
L/M Guide Rail
Coupling
Grease
Ni
pp
le