cp45ref.pdf - 第68页
Samsung Component Placer CP-45F(V)/FS Refer ence Manual 2-14 $3201 Can't move the PCB in the waiting sensor ar ea. $3202 Can't move the PCB in the mounting sensor ar ea. $3203 Can't move the PCB in the out…

System Messages of the MMI and Solutions
2-13
The sensitivity of the mounting sensor is adjusted incorrectly
The time out value is too low
[Solution]
Remove the dropped PCB and start again.
Remove the mechanical interference.
Adjust the sensitivity of the mounting sensor again.
Adjust the time out value. (Factory setting)
$3103 PCB has not arrived in the output sensor area.
[Problem]
The PCB is dropped during transfer
The PCB is blocked due to mechanical interference during transfer
The sensitivity of the take out sensor is adjusted incorrectly
The time out value is too low
[Solution]
Remove the dropped PCB and start again.
Remove the mechanical interference.
Adjust the sensitivity of the output sensor again.
Adjust the time out value. (Factory setting)
$3104 Error occurred during PCB output
[Problem]
The PCB is not taken out completely
The PCB is blocked due to mechanical interference during transfer
The sensitivity of the output sensor is adjusted incorrectly
When the time out value is too low
[Solution]
Find the cause and take corrective measures.
Remove the mechanical interference.
Adjust the sensitivity of the output sensor again.
Adjust the time out value. (Factory setting)

Samsung Component Placer CP-45F(V)/FS Reference Manual
2-14
$3201 Can't move the PCB in the waiting sensor area.
$3202 Can't move the PCB in the mounting sensor area.
$3203 Can't move the PCB in the output sensor area.
$3301 Can't raise the wait stopper.
[Problem]
The wait stopper can't be raised due to mechanical interference
The position of the wait stopper is incorrect.
[Solution]
Remove the mechanical interference.
Adjust the position of the sensor after checking whether it operates or not.
$3302 Can't lower the wait stopper.
[Problem]
The wait stopper can't be lowered due to mechanical interference
The position of the wait stopper is incorrect.
[Solution]
Remove the mechanical interference.
Check if the sensor operates properly and adjust its position
$3401 Can't raise the work stopper.
[Problem]
The mounting stopper can't be raised due to mechanical interference
The position of the mounting stopper is incorrect
[Solution]
Remove the mechanical interference.
Check if the sensor operates properly and adjust its position

System Messages of the MMI and Solutions
2-15
$3402 Can't lower the work stopper.
[Problem]
The mounting stopper can't be lowered due to mechanical interference
The position of the mounting stopper is incorrect
[Solution]
Remove the mechanical interference.
Check if the sensor operates properly and adjust its position.
$3501 Can't raise the out stopper.
$3502 Can't lower the out stopper.
$3600 AREA_PCB_OVER_MAXIMUM_WARNING.
$3601 MOUNTING_OVER_MAXIMUM_WARNING.
$3700 SMEMA_SIGNAL_TIMEOUT_ERROR.
$3701 Time out error occurred on the conveyor during operation.
[Problem]
Time out occurred during the transfer of PCB on the conveyor.
[Solution]
Correct the problem and restart.
$3fff CONV_NOT_DEFINED
[Problem]
The conveyor related setting is not correct.
[Solution]
Please contact our C/S.