cp45ref.pdf - 第79页

System Messages of the MMI and Solutions 2-25 [Problem] In the component data, there is no nozzle related setting. [Solution] Set the nozzle in the component data. $600d Can't find the nozzle ID to use automatically…

100%1 / 149
Samsung Component Placer CP-45F(V)/FS Reference Manual
2-24
$6007 Invalid PUT nozzle data
[Problem]
S/W error
[Solution]
Please contact our C/S
$6008 Nozzle in the ANC.
[Problem]
A nozzle is in the ANC when the nozzle is to be put.
[Solution]
Check the ANC setting
$6009 No nozzle in the ANC.
[Problem]
There is no nozzle in the ANC when the nozzle is to be put.
[Solution]
Check the ANC setting
$600a Couldn't move to the position of nozzle pick.
[Problem]
S/W error
[Solution]
Please contact our C/S
$600b Check sum of the back up SRAM is incorrect. Initializes the ANC and nozzle data
[Problem]
The ANC setting stored on the CPU board is erased.
[Solution]
Set the ANC setting again.
$600c No nozzle ID in the component Data.
System Messages of the MMI and Solutions
2-25
[Problem]
In the component data, there is no nozzle related setting.
[Solution]
Set the nozzle in the component data.
$600d Can't find the nozzle ID to use automatically
[Problem]
The nozzle specified in the component is not in the ANC.
[Solution]
Set the ANC again.
$600e Can't find the nozzle ID to use automatically
[Problem]
The nozzle specified in the component is not in the ANC.
[Solution]
Set the ANC again.
$600f Incorrect nozzle length.
[Problem]
Incorrect nozzle length is registered.
[Solution]
Check the nozzle length of the System.
$6010 Z axis can't move to the position of the nozzle check sensor.
[Problem]
The position of nozzle inspection is set incorrectly.
[Solution]
Check the setting of the nozzle inspection position of the System.
$6020 Can't put, no nozzle in the head.
Samsung Component Placer CP-45F(V)/FS Reference Manual
2-26
[Problem]
No nozzle is in the head.
[Solution]
Check the ANC setting.
$6030 Nozzle in the head. Can't put.
[Problem]
Checking after putting the nozzle reveals there is a nozzle in the head
[Solution]
Check the Z axis height in the ANC.
Check the operation of the nozzle check sensor.
$6040 Z axis couldn't move to the put position.
[Problem]
S/W error
[Solution]
Please contact our C/S.
$6050 Z axis couldn't move to a safe height after putting.
[Problem]
S/W error
[Solution]
Please contact our C/S.
$6060 Can't get, nozzle in the head.
[Problem]
Can't get a nozzle because there is a nozzle in the head.
[Solution]
Check the ANC setting
Check the nozzle check sensor.