cp45ref.pdf - 第78页

Samsung Component Placer CP-45F(V)/FS Refer ence Manual 2-24 $6007 Invalid PUT nozzle data [Problem] S/W error [Solution] Please contact our C/S $6008 Nozzle in the ANC. [Problem] A nozzle is in the ANC when the nozzle i…

100%1 / 149
System Messages of the MMI and Solutions
2-23
Check the position of the sensor.
$6003 Can't close the ANC.
[Problem]
The ANC can't be closed due to mechanical interference
The position of the ANC sensor is incorrect
[Solution]
Check if there is any mechanical interference.
Check the position of the sensor.
$6004 XY couldn't move to the nozzle put position.
[Problem]
H/W error
[Solution]
Check the XY-Axis board.
Check the wiring related to XY.
$6005 Can't find the Z axis PORT.
[Problem]
Equipment setting is incorrect
S/W error
[Solution]
Check the Config and factory setting.
Please contact our C/S.
$6006 SET_AXIS_ADDON_ERROR.
[Problem]
S/W error
[Solution]
Please contact our C/S
Samsung Component Placer CP-45F(V)/FS Reference Manual
2-24
$6007 Invalid PUT nozzle data
[Problem]
S/W error
[Solution]
Please contact our C/S
$6008 Nozzle in the ANC.
[Problem]
A nozzle is in the ANC when the nozzle is to be put.
[Solution]
Check the ANC setting
$6009 No nozzle in the ANC.
[Problem]
There is no nozzle in the ANC when the nozzle is to be put.
[Solution]
Check the ANC setting
$600a Couldn't move to the position of nozzle pick.
[Problem]
S/W error
[Solution]
Please contact our C/S
$600b Check sum of the back up SRAM is incorrect. Initializes the ANC and nozzle data
[Problem]
The ANC setting stored on the CPU board is erased.
[Solution]
Set the ANC setting again.
$600c No nozzle ID in the component Data.
System Messages of the MMI and Solutions
2-25
[Problem]
In the component data, there is no nozzle related setting.
[Solution]
Set the nozzle in the component data.
$600d Can't find the nozzle ID to use automatically
[Problem]
The nozzle specified in the component is not in the ANC.
[Solution]
Set the ANC again.
$600e Can't find the nozzle ID to use automatically
[Problem]
The nozzle specified in the component is not in the ANC.
[Solution]
Set the ANC again.
$600f Incorrect nozzle length.
[Problem]
Incorrect nozzle length is registered.
[Solution]
Check the nozzle length of the System.
$6010 Z axis can't move to the position of the nozzle check sensor.
[Problem]
The position of nozzle inspection is set incorrectly.
[Solution]
Check the setting of the nozzle inspection position of the System.
$6020 Can't put, no nozzle in the head.