cp45ref.pdf - 第52页
Samsung Component Placer CP-45F(V)/FS Refer ence Manual 1-26 1.3. Noise Solution Caution When a noise problem applying to one of above classification occurs and if the machine i s operated without correcting the probl em…

Preventive Maintenance
1-25
Lower the locking mechanism or handle for the air filter tray and turn it sideways to
remove the tray.
Remove the contaminated filter element.
Install the new filter element reversing the above procedures.
Reassemble the tray.
1.2.7.3. Gauge and Pressure Switch
Inspection
Check to see if the pressure switch has been automatically activated by low pressure.
Solution
If it does not function properly, contact the service center for service.
1.2.7.4. Connections and Fittings
Inspection
Check for unusual wear in the tubes.
Check to see if any tubes and fittings are loose, and make sure there are no leaks.
Solution
Replace the tube if unusual wear is discovered.
Tighten any loose fitting.
1.2.8. Component Feeding Sub-Systems (Feeders)
Please refer to the manuals for information on each component feeding sub-systems.

Samsung Component Placer CP-45F(V)/FS Reference Manual
1-26
1.3. Noise Solution
Caution
When a noise problem applying to one of above classification occurs
and if the machine is operated without correcting the problem, it will
affect the life span of the machine. Be sure to operate the machine
after taking proper corrective actions.
Classification Noise Type Possible Cause Sloution
X,Y Axis
noise
.Resonance on
driving motor
.Motor drive failure or abnormal
motor gains.
.Contact Samsung srevice
Center
.Coupling vibration .Coupling bolt is not tightened. .Tighten up the bolt as the
prescribed torque.
.Loud metalic suond
on ball screw
.Metal contact due to insufficient
lubrication.
.Grease the ball screw.
.Irregular meatalic
sound on LM guide
.Small chips or dusts are stuck on
the LM Guide surface.
.Metal contact due to insufficient
lubrication.
.Clean the LM guide suface
.Replenish grease.
Conveyor noise
.PCB driving belt
.Loud metalic noise
on adjusting
conveyor width
.Belt tension is too tight or too
loose.
.Small Chips or dusts are stuck
on the belt or pulley surface.
.Metal contact due to insufficient
lubrication.
.Adjust the belt tension.
.Clean the pulley surface.
.Grease the screws for
adjusting width.
Z Axis
noise
.Loud sound on
driving motor
.Belt tension is too tight.
.Small chips or parts exist
between belt and pulley.
.Adjust the belt tension.
.Remove the interfering
substances in belt or
pulley.
Air pipes
.Air leakage .Air pipes' failure. .Check where the air
leakage occurs and replace
it.
Fan
.Air resistance
noise
.Small Chips or dusts are stuck
on the Fan cover.
.Clean the fan cover hole.

Troubleshooting
Guide
The "Troubleshooting Guide" contains detailed information of the error code and
solutions for MMI and for troubleshooting for hardware.