System Messages of the MMI and Solutions 2-23 Check the position of the sensor . $6003 Can't close the ANC. [Problem] The ANC can 't be closed due to mechanical interference The position of the ANC sensor is in…

100%1 / 149
Samsung Component Placer CP-45F(V)/FS Reference Manual
2-22
$5800 Vacuum check error in the component $P supplied from the feeder $F.
[Problem]
An error occurs when the supplied component is checked for vacuum.
There is no supplied component
The vacuum level is set incorrectly
The vacuum sensor is abnormal
[Solution]
Supply components.
Check the vacuum level of the nozzle in the System device.
Check the vacuum and if there is any abnormality, replace it.
$5801 Vision check error in the component $P supplied from the feeder $F.
[Problem]
An error occurs when the supplied component is vision checked.
There is no component
[Solution]
Supply components.
$6001 Can't open the mirror.
[Problem]
Can't open the mirror
[Solution]
Please contact our C/S.
$6002 Can't open the ANC.
[Problem]
The ANC can't be opened due to mechanical interference
The position of the ANC sensor is incorrect
[Solution]
Check if there is any mechanical interference.
System Messages of the MMI and Solutions
2-23
Check the position of the sensor.
$6003 Can't close the ANC.
[Problem]
The ANC can't be closed due to mechanical interference
The position of the ANC sensor is incorrect
[Solution]
Check if there is any mechanical interference.
Check the position of the sensor.
$6004 XY couldn't move to the nozzle put position.
[Problem]
H/W error
[Solution]
Check the XY-Axis board.
Check the wiring related to XY.
$6005 Can't find the Z axis PORT.
[Problem]
Equipment setting is incorrect
S/W error
[Solution]
Check the Config and factory setting.
Please contact our C/S.
$6006 SET_AXIS_ADDON_ERROR.
[Problem]
S/W error
[Solution]
Please contact our C/S
Samsung Component Placer CP-45F(V)/FS Reference Manual
2-24
$6007 Invalid PUT nozzle data
[Problem]
S/W error
[Solution]
Please contact our C/S
$6008 Nozzle in the ANC.
[Problem]
A nozzle is in the ANC when the nozzle is to be put.
[Solution]
Check the ANC setting
$6009 No nozzle in the ANC.
[Problem]
There is no nozzle in the ANC when the nozzle is to be put.
[Solution]
Check the ANC setting
$600a Couldn't move to the position of nozzle pick.
[Problem]
S/W error
[Solution]
Please contact our C/S
$600b Check sum of the back up SRAM is incorrect. Initializes the ANC and nozzle data
[Problem]
The ANC setting stored on the CPU board is erased.
[Solution]
Set the ANC setting again.
$600c No nozzle ID in the component Data.