KE-2050R-2055R-2060R维修调整要领书.pdf - 第234页
R E V 1 . 0 0 维修调整要领书 −−−−− −−−−−−−−−−−−−−−−− −−−−− (R )−CN16 未使用 −−−−− −−−−−−−−−−−−−−−−− −−−−− (R )−CN17 未使用 −−−−− −−−−−−−−−−−−−−−−− −−−−− (R )−CN18 未使用 40002163 FD-FLOAT(RR)CABLE ASM CN419R (R)−CN19 40002165 FD-SENS CA…

REV1.00
维修调整要领书
图14−7−1−3 CARRY中转基板的连接
表14−7−1−3 CARRY中转基板的连接
对象电缆
货 号 品 名 插头号码
CARRY传
感器中转基板
连接部位
备 考
40002073 CRY-SENS(R)CABLE ASM CN421 (R)−CN1
40002128 ATC-OPEN SENS ASM CN402R (R)−CN2
40002127 ATC-CLOSE SENS ASM CN403R (R)−CN3
−−−−− −−−−−−−−−−−−−−−−− −−−−− (R)−CN4 未使用
−−−−− −−−−−−−−−−−−−−−−− −−−−− (R)−CN5 未使用
−−−−− −−−−−−−−−−−−−−−−− −−−−− (R)−CN6 未使用
−−−−− −−−−−−−−−−−−−−−−− −−−−− (R)−CN7 未使用
−−−−− −−−−−−−−−−−−−−−−− −−−−− (R)−CN8 未使用
40002121 AWC ORG CABLE ASM CN409R (R)−CN9 AWC 选购品时
−−−−− −−−−−−−−−−−−−−−−− −−−−− (R)−CN10 未使用
−−−−− −−−−−−−−−−−−−−−−− −−−−− (R)−CN11 未使用
40002178 AIR PRESSRE CABLE ASM CN412R (R)−CN12
40002166 FD-SENS RCV CABLE ASM
40003250 SHORT WIRE ASM(C)
CN413R (R)−CN13
40002160 FD-FLOAT(FR)RCV CABLE ASM CN414R (R)−CN14
40002162 FD-FLOAT(RF)RCV CABLE ASM CN415R (R)−CN15
装置正面
CARRY传感器中转基板(R)
插头号码
CN421,CN402R~CN420R
CARRY传感器中转基板(L)
插头号码
CN401,CN402L~CN420L
14-41

REV1.00
维修调整要领书
−−−−− −−−−−−−−−−−−−−−−− −−−−− (R)−CN16 未使用
−−−−− −−−−−−−−−−−−−−−−− −−−−− (R)−CN17 未使用
−−−−− −−−−−−−−−−−−−−−−− −−−−− (R)−CN18 未使用
40002163 FD-FLOAT(RR)CABLE ASM CN419R (R)−CN19
40002165 FD-SENS CABLE ASM CN420R (R)−CN20
40002074 CRY-SENS(L)CABLE ASM CN401 (L)−CN1
40002209 IN SENS CABLE ASM CN402L (L)−CN2
40002211 OUT SENS CABLE ASM CN403L (L)−CN3
40002213 WAIT SENS CABLE ASM CN404L (L)−CN4
40002242 BU LOCK CABLE ASM(EN) CN405L (L)−CN5 EN 规格时
−−−−− −−−−−−−−−−−−−−−−− −−−−− (L)−CN6 未使用
40002123 T.PIN CABLE SAM CN407L (L)−CN7
40002240 BU PIN RV CABLE ASM CN408L (L)−CN8 AWC 选购件时
40002124 BU ORG SENS ASM
40002345 BU ORG RLY CABLE ASM
CN409L (L)−CN9
只有深基准时
−−−−− −−−−−−−−−−−−−−−−− −−−−− (L)−CN10 未使用
−−−−− −−−−−−−−−−−−−−−−− −−−−− (L)−CN11 未使用
−−−−− −−−−−−−−−−−−−−−−− −−−−− (L)−CN12 未使用
−−−−− −−−−−−−−−−−−−−−−− −−−−− (L)−CN13 未使用
40002158 FD-FLOAT(FF)RCV CABLE ASM CN414L (L)−CN14
40002164 FD-FLOAT(RR)RCV CABLE ASM CN415L (L)−CN15
40002236 C.OUT SENS CABLE ASM CN416L (L)−CN16
40002215 STOP SENS CABLE ASM CN417L (L)−CN17
40002159 FD-FLOAT(FR)CABLE ASM CN418L (L)−CN18
40002161 FD-FLOAT(RF)CABLE ASM CN419L (L)−CN19
40002238 BU PIN CABLE ASM CN420L (L)−CN20 AWC 选购件时
14-42

REV1.00
维修调整要领书
14-7-2.CARRY中转基板的调整
传送装置使用的CARRY中转基板跨接 DIP-SW 交货时已经设定,安装基板组件时请进行确认。
各跨接开关 DIP−SW 的设定如下。
W3 W4 W5 W6 W7
W9
2
1
SW5 SW4 SW3 SW2 SW1
10
9
图中涂抹的部分是设定开关
时开关的设定方向。
贴装头时为跨接部分。
SW1:IN 在硬件设定传感器的传送延迟时间时调整开关。
1:ON 延迟时间为 10msec。
2:ON 延迟时间为 20msec。
3:ON 延迟时间为 40msec。
4:ON 延迟时间为 80msec。
W1:IN 传感器延迟时间硬件控制的 ON/OFF 变换。开放:ON/短接:OFF
SW 2:WAIT 在硬件设定传感器的传送延迟时间的调整开关。
开关设定与 SW1 相同。
W2:WAIT 传感器延迟时间硬件控制的 ON/OFF 变换。开放:ON/短接:OFF
SW 3:OUT 在硬件设定传感器的传送延迟时间的调整开关。
开关设定与 SW1 相同。
W3:OUT 传感器延迟时间硬件控制的 ON/OFF 变换。开放:ON/短接:OFF
SW 4:STOP(L) 在硬件设定传感器的传送延迟时间的调整开关。
开关设定与 SW1 相同。
W4:STOP(L) 传感器延迟时间硬件控制的 ON/OFF 变换。开放:ON/短接:OFF
SW 5:C.OUT(L) 在硬件设定传感器的传送延迟时间的调整开关。
开关设定与 SW1 相同。
W5:C.OUT(L) 传感器延迟时间硬件控制的 ON/OFF 变换。
开放:ON/
短接:OFF
14-43