UV-9+Cure+Module+7269348_B+Manual.pdf - 第19页

Table 1-4 Rear View Features Item Name Description 1 Exhaust Port The 152.4 mm (6 in) diameter exhaust port at taches to the ducting of the facility ventilat ion system. Heat and hazardous vapors produced in the curing p…

100%1 / 142
1.9.2 Rear View Features
Figure 1-2 and Table 1-4 describe the rear exterior features of the UV-9 Cure Module.
Figure 1-2 Rear View
1
3
2
4
5
6
1-6 Introduction
Table 1-4 Rear View Features
Item
Name
Description
1 Exhaust Port
The 152.4 mm (6 in) diameter exhaust port attaches to the ducting of the
facility ventilation system. Heat and hazardous vapors produced in the
curing process are safely removed from the UV-9 Cure Module.
2
Rear Enclosure
Access Panels
The rear access panel provides access to the UV lamp power supply
network and main power electrical connections.
3
Upstream
SMEMA Port
The upstream SMEMA connector allows for communication between the
UV-9 Cure Module and an upstream machine.
4 E-Stop Button
Cuts power to all system components. See 2.10 Emergency Shutdown for
detailed information.
5
Main Power
Switch
The Main Power Switch is mechanically connected to the Main Circuit
Breaker in the electronics enclosure. A flange on the switch housing allows it
to be locked in the OFF (I) position during servicing. Switching off the Main
Power Switch cuts power to all system components.
6
Downstream
SMEMA Port
The downstream SMEMA connector allows for communication between the
UV-9 Cure Module and a downstream machine.
Introduction 1-7