Table 1-4 Rear View Features
Item
Name
Description
1 Exhaust Port
The 152.4 mm (6 in) diameter exhaust port attaches to the ducting of the
facility ventilation system. Heat and hazardous vapors produced in the
curing process are safely removed from the UV-9 Cure Module.
2
Rear Enclosure
Access Panels
The rear access panel provides access to the UV lamp power supply
network and main power electrical connections.
3
Upstream
SMEMA Port
The upstream SMEMA connector allows for communication between the
UV-9 Cure Module and an upstream machine.
4 E-Stop Button
Cuts power to all system components. See 2.10 Emergency Shutdown for
detailed information.
5
Main Power
Switch
The Main Power Switch is mechanically connected to the Main Circuit
Breaker in the electronics enclosure. A flange on the switch housing allows it
to be locked in the OFF (I) position during servicing. Switching off the Main
Power Switch cuts power to all system components.
6
Downstream
SMEMA Port
The downstream SMEMA connector allows for communication between the
UV-9 Cure Module and a downstream machine.
Introduction 1-7

2 Safety
2.1 Overview
This section is intended to provide basic safety information necessary for operating, maintaining, and
servicing your UV-9 Cure Module. This section covers the following topics:
• Facility Requirements
• Residual Safety Risks
• Equipment Usage
• Emergency Shutdown
• Basic Safety Precautions and Practices
• Service Shutdown
• Disposal
• Lockout/Tagout of Electrical Energy
• Lifting and Transport Precautions
• Integrated Safety Systems
• Earthquake Precautions
• Transportation and Storage
• Safety Warning Labels
To further optimize safe operation, maintenance, and servicing of the UV-9 Cure Module, precautions
and recommended practices are included with the procedures throughout this manual.
WARNING! CAUTION!
Unsafe equipment conditions can result in personal injury or property damage.
Failure to properly operate and maintain the UV-9 Cure Module in accordance
with this manual may jeopardize the built-in safety features.
NOTE Safety is considered a joint responsibility between the original equipment manufacturer
(Nordson ASYMTEK) and the end-user (owner). Safety precautions and practices should
be in accordance with local laws, regulations, and facility requirements in addition to
those recommended in this manual.
2.2 Facility Requirements
To ensure optimal performance and safety, it is necessary to install the oven and its components in a
facility that meets the requirements listed in 8.3 Facility Requirements. If you have any questions about
facility requirements, please contact Nordson ASYMTEK Technical Support.
Safety 2-1