12 Smart Slaves DRT2 Series
Functions Supported by Smart Slaves
OK: Function supported, ---: Function not supported.
*1. The operation time monitor cannot be used with the DRT2-@D08(-1).
*2. Expansion Units cannot be added with the DRT2-@D08(-1) or DRT2-MD16(-1).
Notice: The contact operation counter function and the total ON time monitor function cannot be used simultaneously for the same contact.
Function
General Slaves
Remote I/O Terminals
Transistors Relays Transistors with 3-tier terminal block
Input Output I/O Output Input Output I/O
Operation time monitor OK (Input+Output only) *1OK
Contact operation counter OK
Unit conduction time monitor OK
Total ON time monitor OK
Unit comments OK
Connected device comments OK
Network power supply voltage monitor OK
I/O power supply monitor OK --- OK
Communications error log monitor OK
Input filter OK --- OK --- OK --- OK
Power-ON inrush current protection OK --- OK --- OK --- OK
Sensor power supply short-circuit
detection
---
Disconnected sensor detection ---
External load short-circuit detection ---
Disconnected sensor detection ---
Removable terminal block OK
Communications speed auto-detect OK
No need to wire Unit power supply OK
No need to wire input device power
supply
---
Expansion via Expansion I/O Units OK *2 --- --- ---
Scaling ---
User compensation ---
Last maintenance date OK
Cumulative counter ---
Moving average processing ---
Number of A/D conversion points
(conversion cycle) setting
---
Peak/bottom hold ---
Top/valley hold ---
Percentage change calculation ---
Comparator ---
Selectable output value after error ---
Smart Slaves DRT2 Series 13
OK: Function supported, ---: Function not supported.
Notice: The contact operation counter function and the total ON time monitor function cannot be used simultaneously for the same contact.
Function
General Slaves
Connector Terminals
e-CON Connector Board Terminals with MIL Connector
Input I/O Input Output I/O
Operation time monitor --- OK OK
Contact operation counter OK
Unit conduction time monitor OK
Total ON time monitor OK
Unit comments OK
Connected device comments OK
Network power supply voltage monitor OK
I/O power supply monitor --- OK
Communications error log monitor OK
Input filter OK OK --- OK
Power-ON inrush current protection OK OK --- OK
Sensor power supply short-circuit
detection
OK ---
External load disconnection detection ---
External load short-circuit detection --- OK ---
Disconnected sensor detection ---
Removable terminal block ---
Communications speed auto-detect OK
No need to wire Unit power supply OK
No need to wire input device power
supply
OK ---
Expansion via Expansion I/O Units ---
Scaling ---
User compensation ---
Last maintenance date OK
Cumulative counter ---
Moving average processing ---
Number of A/D conversion points
(conversion cycle) setting
---
Peak/bottom hold ---
Top/valley hold ---
Percentage change calculation ---
Comparator ---
Selectable output value after error ---
14 Smart Slaves DRT2 Series
OK: Function supported, ---: Function not supported.
Notice: The contact operation counter function and the total ON time monitor function cannot be used simultaneously for the same contact.
Note: The DRT2-OD32SLH-1/MD32SLH-1 of unit version 2.0 or higher support External load short-circuit detection function.
Function
General Slaves
Screw-less clamp terminals
DRT2-@D16SLH
(Detection function)
DRT2-@D16SL
(No detection function)
DRT2-@D32SLH
(Detection function)
Input Output Input Output Input Output I/O
Operation time monitor OK
Contact operation counter OK
Unit conduction time monitor OK
Total ON time monitor OK
Unit comments OK
Connected device comments OK
Network power supply voltage monitor OK
I/O power supply monitor OK
Communications error log OK
Input filter OK --- OK --- OK --- OK
Power-ON inrush current protection OK --- OK --- OK --- OK
Sensor power supply short-circuit
detection
OK --- --- OK --- OK
External load disconnection detection OK --- --- OK --- OK
External load short-circuit detection --- OK --- ---
OK
(See Note.)
OK
(See Note.)
Disconnected sensor detection --- OK --- --- OK OK
Removable terminal block OK
Communications speed auto-detect OK
No need to wire Unit power supply OK
No need to wire input device power
supply
---
Expansion via Expansion I/O Units ---
Scaling ---
User compensation ---
Last maintenance date OK
Cumulative counter ---
Moving average processing ---
Number of A/D conversion points
(conversion cycle) setting
---
Peak/bottom hold ---
Top/valley hold ---
Percentage change calculation ---
Comparator ---
Selectable output value after error ---