drt2_devicenet_q102-e1_20_22_csm2147.pdf - 第34页
14 Smart Slaves DRT2 Series OK: Function supported, ---: Function not supported. Notice: The contact operation counter function and the total ON time monitor function cannot b e used simultaneously for the same contact. …

Smart Slaves DRT2 Series 13
OK: Function supported, ---: Function not supported.
Notice: The contact operation counter function and the total ON time monitor function cannot be used simultaneously for the same contact.
Function
General Slaves
Connector Terminals
e-CON Connector Board Terminals with MIL Connector
Input I/O Input Output I/O
Operation time monitor --- OK OK
Contact operation counter OK
Unit conduction time monitor OK
Total ON time monitor OK
Unit comments OK
Connected device comments OK
Network power supply voltage monitor OK
I/O power supply monitor --- OK
Communications error log monitor OK
Input filter OK OK --- OK
Power-ON inrush current protection OK OK --- OK
Sensor power supply short-circuit
detection
OK ---
External load disconnection detection ---
External load short-circuit detection --- OK ---
Disconnected sensor detection ---
Removable terminal block ---
Communications speed auto-detect OK
No need to wire Unit power supply OK
No need to wire input device power
supply
OK ---
Expansion via Expansion I/O Units ---
Scaling ---
User compensation ---
Last maintenance date OK
Cumulative counter ---
Moving average processing ---
Number of A/D conversion points
(conversion cycle) setting
---
Peak/bottom hold ---
Top/valley hold ---
Percentage change calculation ---
Comparator ---
Selectable output value after error ---

14 Smart Slaves DRT2 Series
OK: Function supported, ---: Function not supported.
Notice: The contact operation counter function and the total ON time monitor function cannot be used simultaneously for the same contact.
Note: The DRT2-OD32SLH-1/MD32SLH-1 of unit version 2.0 or higher support External load short-circuit detection function.
Function
General Slaves
Screw-less clamp terminals
DRT2-@D16SLH
(Detection function)
DRT2-@D16SL
(No detection function)
DRT2-@D32SLH
(Detection function)
Input Output Input Output Input Output I/O
Operation time monitor OK
Contact operation counter OK
Unit conduction time monitor OK
Total ON time monitor OK
Unit comments OK
Connected device comments OK
Network power supply voltage monitor OK
I/O power supply monitor OK
Communications error log OK
Input filter OK --- OK --- OK --- OK
Power-ON inrush current protection OK --- OK --- OK --- OK
Sensor power supply short-circuit
detection
OK --- --- OK --- OK
External load disconnection detection OK --- --- OK --- OK
External load short-circuit detection --- OK --- ---
OK
(See Note.)
OK
(See Note.)
Disconnected sensor detection --- OK --- --- OK OK
Removable terminal block OK
Communications speed auto-detect OK
No need to wire Unit power supply OK
No need to wire input device power
supply
---
Expansion via Expansion I/O Units ---
Scaling ---
User compensation ---
Last maintenance date OK
Cumulative counter ---
Moving average processing ---
Number of A/D conversion points
(conversion cycle) setting
---
Peak/bottom hold ---
Top/valley hold ---
Percentage change calculation ---
Comparator ---
Selectable output value after error ---

Smart Slaves DRT2 Series 15
OK: Function supported, ---: Function not supported.
* The operation time monitor can be used with the DRT2-@D04CL(-1).
Notice: The contact operation counter function and the total ON time monitor function cannot be used simultaneously for the same contact.
Function
Environment-resistive Slaves
Analog Slaves
Analog I/O Terminals
Temperature
Input Terminals
Advanced Model Standard Model DRT2-AD04 DRT2-AD04H DRT2-DA02
Input Output Input Output I/O Input Output Input
Operation time monitor --- --- * OK --- ---
Contact operation counter OK --- ---
Unit conduction time monitor OK OK OK
Total ON time monitor OK --- ---
Unit comments OK OK OK
Connected device comments OK OK OK
Network power supply voltage monitor OK OK OK
I/O power supply monitor --- OK OK --- ---
Communications error log --- OK OK OK OK
Input filter OK --- OK --- OK --- ---
Power-ON inrush current protection OK --- OK --- OK --- ---
Sensor power supply short-circuit
detection
OK --- --- --- ---
External load disconnection detection OK --- --- --- ---
External load short-circuit detection --- OK --- --- ---
Disconnected sensor detection --- --- ---
Removable terminal block --- OK OK
Communications speed auto-detect OK OK OK
No need to wire Unit power supply OK OK OK
No need to wire input device power
supply
OK --- --- --- ---
Expansion via Expansion I/O Units --- --- ---
Scaling --- OK OK
User compensation --- OK OK
Last maintenance date OK OK OK
Cumulative counter --- OK OK
Moving average processing --- OK OK --- OK
Number of A/D conversion points
(conversion cycle) setting
--- OK --- --- ---
Peak/bottom hold --- OK OK --- OK
Top/valley hold --- OK OK --- OK
Percentage change calculation --- OK OK --- OK
Comparator --- OK OK --- OK
Selectable output value after error --- --- --- OK ---
Top/valley count --- --- OK
Operating time in preset temperature --- --- OK
Temperature difference detection
between input channels
--- --- OK