创建组件识别数据的方法.pdf - 第37页
37/178 IM-SMT-VSNDI C-0002 -000 < Items to be s et for SOP > Items to be set Set va lue Alignment Group IC Alignment T ype SOP Comp. Threshold 50 Comp. T olerance 30 Search Are a (mm) 5.0 Body Size X (m m) 6.4 Body…

36/178
IM-SMT-VSNDIC-0002-000
Items to be set Set value
Explanation
Body Size X (mm) Sets the size of the outer edge.
Body Size Y (mm) Sets the size of the outer edge.
Body Size Z (mm) Sets the size of the outer edge.
Ruler Offset Sets the offset amount for the detection line.
Ruler Width
Lead Number
Sets the number of leads on one side.
Lead Pitch (mm)
Sets the pitch.
Lead Width (mm)
Sets the width of the lead.
Reflect LL. (mm)
Sets the lead length on the image.
Table 22
This is the recognition mode used for standard SOP components.
Figure 29
[Recognition check items ]
Items Yes / No Notes
Body Size May exist Only the “Body Size X” is checked.
(Note 1)
Lead pitch Yes
Lead width
May exist
Checks only when the lead width is more than 1.0mm.
(Note 2)
Reflect LL No
Find Pos May exist
Checks the lead tip position using [outer edge
dimension Y x tolerance] as check range.
(Note 3)
Table 23
Note:
1. This function performs a check only when the check function is validated in the
Application software. (Some versions may not be equipped with this function.)
2. “Lead width” check function may not be available for the old versions.
3. See “Appendix 4. Lead position check” for the details of the “Lead position check”
function.
The following is the example of actual setting and the recognition result.
Body Size Y
Body Size X
Lead length
Lead width
Lead pitch

37/178
IM-SMT-VSNDIC-0002-000
< Items to be set for SOP>
Items to be set Set value
Alignment Group IC
Alignment Type SOP
Comp. Threshold 50
Comp. Tolerance 30
Search Area (mm) 5.0
Body Size X (mm) 6.4
Body Size Y (mm) 10.15
Body Size Z (mm) 2.1
Ruler Offset 3
Ruler Width 3
Lead Number 8
Lead Pitch (mm) 1.27
Lead Width (mm) 0.45
Reflect LL. (mm) 0.5
Table 24
<Recognition result>
Figure 30
2.4-1 Special recognition in the SOP Recognition mode
There are some special recognition algorithms for SOP Recognition mode.
<< Items to be set for SOP special mode >>
Items to be set Set value
Explanation
Alignment Group Special Sets the component category.
Common
Data
Alignment Type Special Sets the component type.

38/178
IM-SMT-VSNDIC-0002-000
Items to be set Set value
Explanation
Comp. Threshold
Sets the detection level difference for lead
detection. (
See “Appendix 2. Detection level
differences used to detect leads (threshold
value)”.)
Comp. Tolerance
Specifies the tolerance of lead pitch as a
percentage.
Search Area (mm)
Sets the range of the detection.
Body Size X (mm)
Sets the size of the outer edge.
Body Size Y (mm)
Sets the size of the outer edge.
Body Size Z (mm)
Sets the size of the outer edge.
Cntr. Offset X
(mm)
Sets the offset amount in the X direction
from the center position.
Cntr. Offset Y
(mm)
Sets the offset amount in the Y direction
from the center position.
Cntr. Offset R
(mm)
Sets the offset amount of the angle of
rotation.
Ruler Width
Algorithm Special n
Selects the recognition algorithm when
using a special algorithm.
Base Alignment SOP
Selects the basic component type when
using a special algorithm.
Vision Option 1 (0) Sets option parameter 1.
Vision Option 2 0 Sets option parameter 2.
Vision Option 3 (0) Sets option parameter 3.
Vision Option 4 (0) Sets option parameter 4.
Items to be set
Set
value
Explanation
Lead Group E 1
Sets the number of Lead Group
in the E direction. (1)
Common
Ruler Offset E
Sets the offset amount for the
detection line in the E direction.
Lead Number: 1E
Sets the number of leads in the
E direction.
Reflect LL.: 1E
(mm)
Sets the lead length on the
image in the E direction.
Lead Width: 1E
(mm)
Sets the width of the lead in the
E direction.
Lead Pitch: 1E
(mm)
Sets the pitch in the E direction.
Find Pos X: 1E
(mm)
Sets the reference position X of
the lead in the E direction.
E
Direction
Group
1
Find Pos Y: 1E
(mm)
Sets the reference position Y of
the lead in the E direction.
Lead Group W 1
Sets the number of Lead Group
in the W direction. (1)
Common
Ruler Offset W
Sets the offset amount for the
detection line in the W direction.
Lead Number:
1W
Sets the number of leads in the
W direction.
W
Direction
Group
1
Reflect LL.: 1W
(mm)
Sets the lead length on the