创建组件识别数据的方法.pdf - 第78页

78/178 IM-SMT-VSNDI C-0002 -000 Items to be set Set value Find Pos X: 1E (m m) 3.0 Find Pos Y : 1E (m m) 1 1.6 Lead Group W 1 Comm on Ruler Offset W 5 Lead Num ber: 1 W 2 Reflect LL.: 1W (mm) 2.0 Lead W idth: 1 W (mm) 0.…

100%1 / 178
77/178
IM-SMT-VSNDIC-0002-000
Figure 60
<<Items to be set for Special 1 connectors>>
Items to be set Set value
Alignment Group Special
Alignment Type Special
Comp. Threshold 50
Comp. Tolerance 30
Search Area (mm) 5.0
Body Size X (mm) 7.0
Body Size Y (mm) 15.0
Body Size Z (mm) 2.0
Cntr. Offset X (mm) 0.0
Cntr. Offset Y (mm) 0.0
Cntr. Offset R (mm) 0.0
Ruler Width 3
Algorithm Special 1
Base Alignment Special
Vision Option 1 0
Vision Option 2 0
Vision Option 3 0
Common
Data
Vision Option 4 0
Lead Group E 1
Common
Ruler Offset E 5
Lead Number: 1E 30
Reflect LL.: 1E (mm) 0.5
Lead Width: 1E (mm) 0.2
E
Direction
Group 1
Lead Pitch: 1E (mm) 0.8
78/178
IM-SMT-VSNDIC-0002-000
Items to be set Set value
Find Pos X: 1E (mm) 3.0
Find Pos Y: 1E (mm) 11.6
Lead Group W 1
Common
Ruler Offset W 5
Lead Number: 1W 2
Reflect LL.: 1W (mm) 2.0
Lead Width: 1W (mm) 0.3
Lead Pitch: 1W (mm) 25.0
Find Pos X: 1W (mm) -0.7
W
Direction
Group 1
Find Pos Y: 1W (mm) 12.5
Table 52
(2) Special 2: Long Connector recognition
This mode is used for positioning by using only the specified number of leads on
both side of the connector.
Option 1: Detecting Numbers of side lead (Five in the example of Figure 61.)
(If 0 is specified, all the leads are used.)
Figure 61
(3) Special 3: Not supported
(4) Special 4: Size check (Normal)
The size of the connector is checked by the ordinary connector
recognition function.
(5) Special 5: Size check (Side Fitting)
The size of the connector is checked by the “Special 1” connector
recognition function.
Note:
Please refer to “Appendix 3. Creating simple data in the special recognition modes” for the
method how to create components data in Special mode
<<Items to be set for the special connector>>
Items to be set Set value
Explanation
Alignment Group Special Sets the component category.
Alignment Type Special Sets the component type.
Comp. Threshold
Sets the threshold value or the level
difference.
(See “Appendix 2. Detection level differences
used to detect leads (threshold value)”)
Comp. Tolerance
Specifies the tolerance of the lead pitch as
a percentage.
Common
Data
Search Area (mm)
Sets the range of the detection.
Only the leads in these sections are used for recognition.(In this example,
recognition is performed by using only the five leads on each side.)
79/178
IM-SMT-VSNDIC-0002-000
Items to be set Set value
Explanation
Body Size X (mm)
Sets the size of the outer edge.
Body Size Y (mm)
Sets the size of the outer edge.
Body Size Z (mm)
Sets the size of the outer edge.
Cntr. Offset X
(mm)
Sets the offset amount in the X direction
from the center position.
Cntr. Offset Y
(mm)
Sets the offset amount in the Y direction
from the center position.
Cntr. Offset R
(mm)
Sets the offset amount of the angle of
rotation.
Ruler Offset Sets the width of the lead detection line.
Ruler Width
Algorithm
Special
1-6
Selects the recognition algorithm when
using a special algorithm.
Base Alignment Special
Selects the basic component type when
using a special algorithm.
Vision Option 1 Sets option parameter 1.
Vision Option 2 Sets option parameter 2.
Vision Option 3 Sets option parameter 3.
Vision Option 4 Sets option parameter 4.
Items to be set
Set
value
Explanation
Lead Group N
Sets the number of the Lead
Group (0-2) in the N direction.
Common
Ruler Offset N
Sets the offset amount of the
detection line in the N direction.
Lead Number: 1N
Sets the number of leads of
Group 1 in the N direction.
Reflect LL.: 1N (mm)
Sets the lead length on the
image of Group 1 in the N
direction.
Lead Width: 1N (mm)
Sets the width of the leads of
Group 1 in the N direction.
Lead Pitch: 1N (mm)
Sets the lead pitch of Group 1
in the N direction.
Find Pos X: 1N (mm)
Sets the reference position X
for the lead of Group 1 in the N
direction.
Group 1
Find Pos Y: 1N (mm)
Sets the reference position Y
for the lead of Group 1 in the N
direction.
Lead Number: 2N
Sets the number of leads of
Group 2 in the N direction.
Reflect LL.: 2N (mm)
Sets the lead length on the
image of Group 2 in the N
direction.
Lead Width: 2N (mm)
Sets the width of the leads of
Group 2 in the N direction.
Lead Pitch: 2N (mm)
Sets the lead pitch of Group 2
in the N direction.
N
Direction
Group 2
Find Pos X: 2N (mm)
Sets the reference position X
for the lead of Group 2 in the N
direction.