OptimaUserManual.pdf - 第49页

QUICK ST ART Opti ma User M anual 43 4. Click YES. When th e p ro grammin g ope ra tio n is co mplet e , t he St at us ar ea of t he Main Program m ing scr een display s t he w ord PAS S:

100%1 / 151
QUICK START
Optima User Manual
42
P
ROGRAM THE
D
EVICE
Now that you have loaded valid data into the programmer’s RAM by reading a Master
Device, you’re ready to program the device. To program the device, follow these
steps:
1. Remove the Master Device from the TOP432.
2. Insert the devices you wish to program into the four sockets of the TOP432.
3. Click Program. You will be asked if you wish to Start Programming Now
.
QUICK START
Optima User Manual
43
4. Click YES.
When the programming operation is complete, the Status area of the Main
Programming screen displays the word PASS:
QUICK START
Optima User Manual
44
Programming a Memory Device on the TOP432 By Loading A
Data File
If you wish to program a memory-based device on the TOP432 and you will be
loading a data file, follow this procedure.
S
ELECT THE DEVICE YOU WISH TO PROGRAM
:
Programming begins by selecting the device you wish to program. To select the
device, follow these steps:
1. Double click the Optima PROM432 icon on the Windows desktop. The Change
Device window displays a device list for the TOP432.
2. Click on the name of the Vendor. When you do that, the Family and Device lists
may change.
3. Click on the general Family of devices. The Device list may change again based
of the Family you chose.