94 Specications of Model MR8740T W aveform screen Display format T ime-domain waveform representation: 1, 2, 4, 8, 16 screens (Up to 64 channels can be displayed on each sheet.) (Every channel can be set to be displayed…

100%1 / 172
93
Specications of Model MR8740T
Trigger mark Trigger marks, which indicate the positions of trigger events, can be displayed.
Trigger timing Start
Alert function The alert function and trigger function other than the analog trigger setting are mutually
exclusive.
Available sampling rate: 100 kS/s or less
When the trigger conditions are satised
Displays and stores channel numbers and measured values, puts marks, and beeps
When the trigger conditions are not satised
Displays and stores channel numbers and measured values, puts marks, and turns off a
buzzer sound.
Auto-trigger level On/Off (for the trigger and alert functions)
Acquires the specied number of values and species the average value of them as the
reference of the window-out trigger.
Choose a number of samples from among 100, 200, 300, 400, and 500.
5
Specications
94
Specications of Model MR8740T
Waveform screen
Display format
Time-domain
waveform
representation:
1, 2, 4, 8, 16 screens
(Up to 64 channels can be displayed on each sheet.)
(Every channel can be set to be displayed on multiple sheets.)
Sheet function Up to 16 sheets
A display format can be chosen for each sheet.
Zoomed display On/Off
Displays time-domain waveforms on the upper waveform screen and zoomed waveforms
on the lower screen.
Full-screen display Maximizes the waveform screen to full screen.
Waveform display Waveform color: Fixed colors (32 colors)
Interpolation: Line
Variable display: Always on
Vernier: Amplitudes of inputted waveforms can be adjusted. (Adjustable
range: 50% to 200% of input)
Grid: Off/On
Logic width: Wide, standard, narrow
Inverted waveform: Polarity-reversed waveforms can be displayed.
(Not available for Model 8967 Temp Unit, Model 8970 Freq Unit, or
Model 8973 Logic Unit)
Zoom in/out Waveforms can be displayed at a preferred magnication.
Waveform scrolling The operator can scroll through waveforms horizontally by dragging the display.
Scrolling through waveforms backward is available during a measurement.
Rolling display Latest data is always displayed following the measurement.
The drawing starting position can be chosen between the left edge and right edge.
(The rolling display is not available when the overlay setting is used.)
Level monitor
function
Numeric value representation
Overlaying
waveforms
Overlaying setting can be selected from off, automatic, manual.
(The rolling display is not available when the overlay setting is used.)
Cursor
Trace cursor: Up to 8 cursors can be displayed.
(Displays potential, time from trigger, time lag between cursors, and
potential difference between cursors.)
Horizontal cursor: Up to 8 cursors can be displayed.
(Displays potential and potential difference between cursors.)
Gauge: Up to 8 cursors can be displayed.
Section designation: Section cursor 1 or section cursor 2
(Species calculation range, save range, and search area.)
Jump: Jumps to the position specied by clicking the screen.
Event mark Event marks can be put during measurement (up to 10,000 marks)
by clicking the start icon or inputting an external signal.
95
Specications of Model MR8740T
Setting screen
Sampling rate Real-time sampling 20 M, 10 M, 5 M, 2 M, 1 M
500 k, 200 k, 100 k, 50 k, 20 k, 10 k, 5 k, 2 k, 1 k
500, 200, 100, 50, 20, 10, 5, 2, 1 [S/s]
For the external sampling setting:
Depends on a signal input to the external sampling terminal.
Up to 10 MHz
For the real-time save
setting
Available maximum sampling rate
When the destination to save data is set to buit-in SSD:
500 kS/s (65 channels or more*)
1 MS/s (33 to 64 channels*)
2 MS/s (13 to 32 channels*)
5 MS/s (12 channels or less*)
When the destination to save data is set to Model Z4006
USB Drive:
100 kS/s (65 channels or more*)
200 kS/s (25 to 64 channels*)
500 kS/s (13 to 24 channels*)
1 MS/s (12 channels or less*)
Only when a drive connects to a USB 3.0 connector
When the destination to save data is set to FTP
transmission:
20 kS/s (65 channels or more*)
50 kS/s (25 to 64 channels*)
100 kS/s (13 to 24 channels*)
200 kS/s (12 channels or less*)
*: When Model U8991 is installed, the number of all
channels increases two times.