MR8740T_Quick guide_eng_20191016H.pdf - 第43页

37 Attaching Connection Cords Output Applicable module Cable to be connected Reference page W aveform Model MR8790 Waveform Generator Unit Model L9795-01 Connection Cable Model L9795-02 Connection Cable p. 49 Pulse Model…

100%1 / 172
36
Attaching Connection Cords
2.2 Attaching Connection Cords
Refer to the manuals of the modules and connection cables if provided.
Measurement Applicable module Cable to be connected
Reference
page
Voltage
Model 8966 Analog Unit
Model 8968 High Resolution Unit
Model 8972 DC/RMS Unit
Model U8975 4ch Analog Unit
Model U8978 4CH Analog Unit
Model U8979 Charge Unit*
Model L9197 Connection Cord
Model L9198 Connection Cord
(For measuring low-voltage)
Model L9217 Connection Cord
Model L9790 Connection Cord
Model 9665 10:1 Probe
Model 9666 100:1 Probe
Model 9322 Differential Probe
Model P9000-01 Differential Probe
Model P9000-02 Differential Probe
Model 9166 Connection Cord*
(For inputting voltage
into Model U8979)
p. 17
p. 38
Frequency
Rotation
speed
Count
Model 8970 Freq Unit
Temperature Model 8967 Temp Unit Thermocouple p. 40
Vibration
Load
Pressure
Acceleration
Torque
Displacement
Model U8969 Strain Unit Strain gauge transducer p. 41
U8979 Charge Unit Acceleration sensor p. 46
Current
Model 8971 Current Unit
Model U8977 3CH Current Unit
(Up to nine current sensors)
Current sensor p. 43
Logic signal
Model 8973 Logic Unit
(Up to 3 modules)
Model 9320-01 Logic Probe
Model MR9321-01 Logic Probe
Model 9327 Logic Probe
p. 48
Voltage
(precision)
Model MR8990 Digital Voltmeter Unit Model L2200 Test Lead p. 48
Model U8991 Digital Voltmeter Unit
Model L9197 Connection Cord
Model L9198 Connection Cord
(for measuring low-voltage)
Model L9217 Connection Cord
Model L9790 Connection Cord
p. 38
High voltage Model U8974 High Voltage Unit
Model L4940 Connection Cable
Set
p. 52
*: Model 9166 Connection Cord can be used for Model U8979 Charge Unit only.
37
Attaching Connection Cords
Output Applicable module Cable to be connected
Reference
page
Waveform Model MR8790 Waveform Generator Unit
Model L9795-01 Connection
Cable
Model L9795-02 Connection
Cable
p. 49
Pulse Model MR8791 Pulse Generator Unit
Commercially available cable
(Half-pitch 50 pins)
p. 50
DC voltage
DC current
Resistance
(simulated)
Model U8794 VIR Generator Unit
Commercially available cable
(D-sub 25 pins)
p. 51
2
Preparing for Measurement
38
Attaching Connection Cords
Connection cables (For measuring voltage, frequency, or rotation
speed, and obtaining accumulations)
Insert connection cords to modules. Choose an appropriate connection cord based on the
maximum input voltage and tips of cables.
The maximum input voltage of the instrument or connection cord, whichever is lower, is applicable.
Refer to “Before connecting cords” (p. 16).
Required items: Connection cords
Connection cord
Maximum input
voltage
Type
Model L9197
Connection Cord
600 V Large alligator clip
Model L9198
Connection Cord
300 V Small alligator clip
Model L9217
Connection Cord
300 V BNC output
Model L9790 Connection Cord
Example: with the alligator clip attached.
600 V Alligator clip
Grabber clip
Contact pin
When the voltage to be measured exceeds the maximum input rating of the module
being used
(excluding Model U8991 Digital Voltmeter Unit)
Model 9665 10:1 Probe*
1
Model 9666 100:1 Probe*
1
Model 9322 Differential Probe*
2
Model P9000-01 Differential Probe*
3
Model P9000-02 Differential Probe*
3
Example: Model P9000-02 Differential Probe
Alligator clip
*1: The maximum rated voltage to earth depends on a module to be used.
*2: An optional power cord or AC adapter is required.
*3: An optional AC adapter or a commercially available USB cable is required.