3OM-996-005.pdf - 第140页

3 . 5 Repetitive Patterns (Unit P .C.B. B.B.R. Function Enabled) Described below are the typical examples of data creation. When the machine is not equipped with the unit P .C.B. B.B.R. function (option), this function c…

100%1 / 385
(4) Placement Data (P-data) U01
Unit Control
Follow the same procedure as described in "3.1 Single Pattern".
Unit P.C.B. B.B.R.
Table 3B28
Unit P.C.B. Recog Coord Recog Coord Recog Coord Recog Coord Fiducial Mark Fiducial Mark
B.B.R. X1 [mm] Y1 [mm] X2 [mm] Y2 [mm] FM1 FM2
Enable FX
1
FY
1
FX
2
FY
2
11
Placement Data (P-data)
Table 3B29
P-No. X [mm] Y [mm] Z
= =
= =
= theta [deg
]]
]]
] H [mm] Fdr. No. V C Comment
1 X
1
Y
1
+000.00 +0.000 101 00 -
2 X
2
Y
2
+090.00 +0.000 103 00 -
3 X
3
Y
3
+180.00 +0.000 105 00 -
4 +000.000 +000.000 +000.00 +0.000 000 00 P
Set "P" or "Q" as a control command in the last line (last step
No.).
(5) Creation of Placement Data (O-data) U01
Table 3B30
O-No. X [mm] Y [mm] Z = theta [deg] C Comment B-X [mm] B-Y [mm]
1 OX
1
OY
1
+000.00 - +000.000 +000.000
2 OX
2
OY
2
+000.00 - +000.000 +000.000
3 OX
3
OY
3
+000.00 - +000.000 +000.000
4 +000.000 +000.000 +000.00 E +000.000 +000.000
0305-001 2-70 AIM01EDTP
3.4 Repetitive Patterns (Unit P.C.B. B.B.R. Enabled)
Note
3.5 Repetitive Patterns (Unit P.C.B. B.B.R. Function
Enabled)
Described below are the typical examples of data creation.
When the machine is not equipped with the unit P.C.B. B.B.R.
function (option), this function cannot be used.
(1) Information on Pattern Program Creation
P.C.B. Size and Packaged Posture & IDs of Components
Follow the same procedure as described in "3.1 Single Pattern".
Placement Coordinates and Angles (Z=Theta)
Fig. 3B131 General View
Fig. 3B132 Pattern 1 (Magnified View)
0305-001 2-71
AIM01EDTP
Placement Coordinate
Reference Point
(OX
1
, OY
1
)
(OX
2
, OY
2
)
Pattern Origin (OX
3
, OY
3
)
Pattern 1
Location of Bad Mark (BX1, BY1)
Pattern 2
Pattern 3
Placement Coordinate
Reference Point
X
3
Y
3
X
2
Y
2
X
1
Y
1
OY
1
OX
1
3.5 Repetitive Patterns (Unit P.C.B. B.B.R. Function Enabled)
Note
Alternate mode Disable
Alternate carriage data
priority processing
Feeder No. offset +000
X/Y table accel des Full Speed
F1 accel des Full Speed
F2 accel des Full Speed
F3 accel des Full Speed
F4 accel des Full Speed
Recovery U-N Disable
regulation
Block Disable
Mode Standard
Unit P.C.B. B.B.R.
Mark Image Dark (E/NR)
(Option)
Component
prechuck
Disable
Sequence Bad Mark
Overall Mode Disable
P.C.B. B.B.R. X [mm]
(Option) Y [mm]
P.C.B. size
P.C.B.
origin offset
X [mm]
Y [mm]
T [mm]
X [mm]
Y [mm]
Z=Theta [deg]
P.C.B. height offset [mm]
P.C.B. Positioning Reference
Pre-Placed component thickness [mm]
Placement mode
P.C.B. transfer speed
Placement data sorting
Feeder standby position
330.000
250.000
1.600
+00.000
+00.000
+0.00
+00.000
Front Right
00.000
Placement
Standard
Standard
000
3.5 Repetitive Patterns (Unit P.C.B. B.B.R. Function Enabled)
(2) Creation of Operation Data
P.C.B. Data
Table 3B31
P.E.C. Recognition Data
Set "Disable" in the "P.E.C. recognition function" text box.
Do not set any parameter in the other text boxes.
P.E.C. Recognition Mark Data
Do not create this data.
Setup Data
Create this data when the automatic setup function should be used.
(3) Creation of Placement Feeder Location Data
Follow the same procedure as described in "3.1 Single Pattern".
0305-001 2-72
AIM01EDTP