(14) [Nozzle Down Error (H)] Button Each text box shows the number of errors in nozzle descending level (H) for each individual nozzles. (15) Component backtrack Shown is the total number of component backtrack errors fo…

100%1 / 385
(4) [B: comp. Missing] Button
Each text box shows the number of missing components de-
tected through recognition operation for each individual nozzles.
(5) [C: comp. Vertical] Button
Each text box shows the number of vertical components detected
by the linear measure detection sensor for each individual nozzles.
(6) [D: comp. Recog.] Button
Each text box shows the number of errors detected through rec-
ognition operation for each individual nozzles.
(7) [E: comp. Thick] Button
Each text box shows the number of errors in component thick-
ness detected by the linear measure detection sensor for each
individual nozzles.
(8) [F: pick-up Diff] Button
Each text box shows the number of pick-up difference errors de-
tected through recognition operation for each individual nozzles.
(9) [G: comp. Reverse] Button
Each text box shows the number of reversed component errors
detected through recognition operation for each individual nozzles.
(10) [Total Errors] Button
Each text box shows the total number of errors detected in (2)
through (9).
(11) [Rate of Error (%)] Button
Each text box shows the percentage of the total number of errors
per the number of picked components.
(12) [Nozzle Clear/Change Date] Button
Each text box shows the clear date for each individual nozzles.
(13) [Nozzle Down Error (L)] Button
Each text box shows the number of errors in nozzle descending
level (L) for each individual nozzles.
3.6 "Nozzle Management Data" Tab
0305-001 4-27 AIM01EDTP
(14) [Nozzle Down Error (H)] Button
Each text box shows the number of errors in nozzle descending
level (H) for each individual nozzles.
(15) Component backtrack
Shown is the total number of component backtrack errors for each
individual nozzles.
(16) Component output error (Pickup error)
Shown is the total number of the output-error-caused compo-
nents (pickup errors) for each individual nozzles.
(17) Component output error (Others)
Shown is the total number of the output-error-caused compo-
nents (errors other than pickup ones) for each individual nozzles.
When one of the above buttons is pressed, the feeder No. with
the biggest parameter under the selected button is displayed in
the first line and feeder Nos. having the subsequent (second,
third, fourth, ...) biggest parameters follow. That is, parameters
are re-arranged in order of error counts (from the biggest to the
smallest ones), making it easy to analyze and improve produc-
tion rate.
When the [Head-Noz.] button is pressed, head-nozzle Nos. are
arranged in their initial order (order of head-nozzle Nos.).
*2 Vertical Scroll Bar
Up and down arrows are located at both ends of a scroll bar. The up
or the down arrow can be pressed to scroll up or down a tab sheet
to expose hidden parameters (data for the hidden head-nozzle Nos.).
*3 Horizontal Scroll Bar
Right and left arrows are located at both ends of a scroll bar. The
right or the left arrow can be pressed to scroll right or left a tab sheet
to expose hidden parameters (data for the hidden head-nozzle Nos.).
0403-002 4-28
AIM01EDTP
3.6 "Nozzle Management Data" Tab
Note
3.7 "Handling/Placement Data" Tab
The corresponding tab sheet enables the operator to view the handling/
placement data.
Sheet Layout
When the "Handling/Placement Data" tab is pressed in the "Manage-
ment Data" window, the following tab sheet appears inside the window.
Fig. 3D14 "Handling/Placement Data" Tab Sheet
Sheet Composition
*1 Description and Count
The following items are displayed.
(1) *Total components
The corresponding "Count" text box shows the number of com-
ponent picks.
*A: component missing [sensor]
The corresponding "Count" text box shows the number of miss-
ing components detected by the linear measure detection sen-
sor.
*B: component missing [recognition]
The corresponding "Count" text box shows the number of miss-
ing components detected through component recognition op-
eration.
*C: component vertical [sensor]
The corresponding "Count" text box shows the number of verti-
cal components detected by the linear measure detection sen-
sor.
*F: pick-up diff
The corresponding "Count" text box shows the number of "Pick-
Up Difference Errors" detected through recognition operation.