3OM-996-005.pdf - 第84页
(A01_03) P .C.B. origin offset X [mm] and Y [mm] Set the offset values to correct the difference between the placement coordinate reference point (N 0 ) and the P .C.B. origin (P 0 ). Unit: mm "Plus" or "M…

(A01_02) P.C.B. size
X [mm], Y [mm], and T [mm]
Set the dimensions of the P.C.B. to be produced.
Unit: mm
Fig. 3B11
When the P.C.B. has a cutout, the following dimensions must
be entered.
Note: TCM-X110 cannot position a P.C.B. that has a cutout
like one in the figure below.
Fig. 3B12
Data Input Range
TCM-X110 TCM-X110M
X: 50 to 330 Y: 50 to 250 T: 0.5 to 5.0
TCM-X210
X: 50 to 460 Y: 50 to 381 T: 0.5 to 5.0
TCM-X300
• P.C.B. Origin Position : [to R460 mm]
X: 50 to 460 Y: 50 to 460 T: 0.5 to 5.0
• P.C.B. Origin Position : [to R510 mm]
X: 50 to 510 Y: 50 to 460 T: 0.5 to 5.0
• P.C.B. Origin Position : [to R560 mm]
X: 50 to 560 Y: 50 to 460 T: 0.5 to 5.0
• P.C.B. Origin Position : [to R610 mm]
X: 50 to 610 Y: 50 to 460 T: 0.5 to 5.0
330.000
250.000
1.600
X [mm]
Y [mm]
T [mm]
Fig. 3B10
2.3 Operation Data
0404-002 2-14 AIM01EDTP
P.C.B.
P.C.B. Flow Direction
Y (Vertical)
X (Horizontal)
T (Thickness)
Y (Vertical)
X (Horizontal)
T (Thickness)
P.C.B.
P.C.B. Flow Direction

(A01_03) P.C.B. origin offset
X [mm] and Y [mm]
Set the offset values to correct the difference between the placement
coordinate reference point (N
0
) and the P.C.B. origin (P
0
).
Unit: mm
"Plus" or "Minus" can be set in both X and Y coordinates in the direc-
tion of the correction.
Fig. 3B14 Example of "+" (Plus) Direction for Correction
P.C.B. Origin(P
0
)
X +
Y +
P.C.B.
Placement Coordinate Reference(N
0
)
P.C.B. Origin(P
0
)
X +
Y +
P.C.B.
Placement Coordinate Reference(N
0
)
TCM-X110
TCM-X210 TCM-X300 TCM-X110M
X [mm]
Y [mm]
+00.000
+00.000
Fig. 3B13
2.3 Operation Data
0404-002 2-15 AIM01EDTP

Z=Theta [deg]
Set the offset value for component placement angle.
The set value is added to the "Z=theta" of all components in the place-
ment data (P data).
To correct the angle of component placement counterclockwise, a
parameter must be entered with a "+" (plus) sign. Put a "-" (minus)
sign to correct it clockwise.
Unit: °(degree)
Fig. 3B16
(A01_04) Placement Angle
"Relative" or "Absolute" can be selected as an angle value
in the text box.
Relative
The normal placement direction is selected.
Absolute
When the component feeding direction differs from one as-
sumed in the component library, it is required to change only
the feeding direction in the component library data. It is not
necessary to change the placement direction in the pattern
program data.
Z=Theta [deg]
Fig. 3B15
+0.00
0°
+.°
-.°
0510-002 2-16 AIM01EDTP
2.3 Operation Data
Relative
Placement Angle
Fig. 3B16-1