3OM-996-005.pdf - 第97页
Overall P .C.B. B.B.R. Detection Function If most of the unit P .C.B.’s are not defective (bad mark attachment not required) but the machine implements the unit P .C.B. bad board reject function on every unit P .C.B., th…

(A01_18) Overall P.C.B. B.B.R. (Option)
When the machine is not equipped with the unit P.C.B.
B.B.R. function (option), this function cannot be used.
Mode
Select one of the following options for the overall P.C.B. B.B.R.
function.
Disable : The overall P.C.B. B.B.R. detection function is not
used.
Enable : The overall P.C.B. B.B.R. detection function is used.
X [mm], Y [mm]
When "Enable" is selected, the coordinates (X and Y) of the bad
mark should be set for the overall P.C.B. B.B.R. detection function.
Unit: mm
0510-002 2-27
AIM01EDTP
2.3 Operation Data
Disable
Mode
Fig. 3B38
Fig. 3B39
X [mm]
Y [mm]
000.00
000.00
Note

Overall P.C.B. B.B.R. Detection Function
If most of the unit P.C.B.’s are not defective (bad mark attachment
not required) but the machine implements the unit P.C.B. bad board
reject function on every unit P.C.B., the production rate of the ma-
chine will deteriorate. To avoid this, the overall P.C.B. B.B.R. detec-
tion function becomes effective.
When this function is activated, the machine implements the overall
P.C.B. B.B.R. detection function to detect a bad mark on the overall
P.C.B. before the implementation of the unit P.C.B. B.B.R. detection
on each unit P.C.B. If no bad mark is detected on the overall P.C.B.,
the machine does not implement the unit P.C.B. B.B.R. detection
function on each unit P.C.B. of the multi-unit P.C.B. because each
unit P.C.B. is considered "Defect-Free".
Fig. 3B40
Placement Coordinate Reference (N0)
Bad Mark for Overall P.C.B. B.B.R. Function
Normal Bad Marks
Y (Vertical)
X (Horizontal)
Placement Coordinate Reference (N0)
Bad Mark for Overall P.C.B. B.B.R. Function
Normal Bad Marks
Y (Vertical)
X (Horizontal)
TCM-X110
TCM-X210 TCM-X300 TCM-X110M
0412-003 2-28 AIM01EDTP
2.3 Operation Data
When "Enable" is set in the "Overall P.C.B. B.B.R."
text box, be sure to put overall P.C.B. B.B.R. bad marks
on the bad-marked P.C.B.’s. Otherwise,
all unit P.C.B.’s are regarded as "Defect-Free".
Note
CAUTION

(A02) P.E.C. Recognition Data
Fig. 3B41 Edit Window (Example)
(A02_01) P.E.C. recognition function
Select one of the following options to determine whether or not this
function should be used.
Disable : The P.E.C. recognition function is not used.
Enable : The P.E.C. recognition function is used.
P.E.C. recognition mode global
When "Enable" is selected, select one of the following options as a
global recognition mode.
Disable : The global recognition function is not activated.
1 Point : The global recognition function is implemented, using one
fiducial mark.
2 Point : The global recognition function is implemented, using two
fiducial marks.
3 Point : The global recognition function is implemented, using three
fiducial marks.
0305-001 2-29
AIM01EDTP
2.3 Operation Data
Enable
P.E.C. recognition function
Fig. 3B42
Fig. 3B43
P.E.C. recognition mode global
2 Point