OperationInstruction_Vsision XP.pdf - 第102页

Page 94 V ISION XP+ V AC 5 Software 5.3 The Menu System Operating Instructions V ersion 1.5 Resetting a P assword A security prom pt appears after cli cking the Reset Pass word button. Fig. 5-2 3 Rese t Password Prompt I…

100%1 / 214
VISION XP+ VAC Page 93
5 Software
5.3 The Menu System
Operating Instructions
Version 1.5
Entering and Changing
Users
In order to enter a new user or change the access codes of an existing user,
move the mouse cursor into a line in the Password Administration function
and double click.
The User Setup window appears.
Fig. 5-22 User Setup
Name
It is advisable to enter the actual name of the user to whom the password
has been assigned. Maximum length is 20 characters, and special charac-
ters can be used. Upper and lower case letters must be correctly entered.
Levels (user authority levels)
Click into the field next to the designation Level. A pull-down menu appears
which includes all possible authority levels. Select and click the desired lev-
el. The highest level which can be selected is the level at which the current
user is logged on
Authority levels range from none to administrator.
Levels including the supplement Adv (Advanced) are higher than the levels
with the same name which do not include this supplement. This means that
the user has more authority.
If the authority level is inadequate, various functions cannot be used. Win-
dows which appear in light gray in the pull-down menus cannot be accessed.
Entry fields which appear in windows with gray backgrounds cannot be
changed.
Note!
User administration can only be adjusted on the level Admin. Thus the ad-
ministrator or the person in charge of the system are never allowed to as-
sign themselves smaller access rights. Afterwards, they have no possibility
to log in there or to distribute this level to other users.
Page 94 VISION XP+ VAC
5 Software
5.3 The Menu System
Operating Instructions
Version 1.5
Resetting a Password A security prompt appears after clicking the Reset Password button.
Fig. 5-23 Reset Password Prompt
If the prompt is acknowledged with Yes, the selected user can log on without
a password. However, the user should enter a new password the next time
he logs on.
5.3.4 Settings
Fig. 5-24 System Settings
This window can only be accessed by service personnel from Rehm Ther-
mal Systems or by the administrator.
VISION XP+ VAC Page 95
5 Software
5.3 The Menu System
Operating Instructions
Version 1.5
Fig. 5-25 System Settings / Authority
Authority
If Automatic Logoff has been acti-
vated, the user is logged off auto-
matically after the specified time has
elapsed, as long as none of the keys
or the mouse are used during this
time (comparable to screen saver
function).
If Do Not Check Data for Changes
has been activated, no prompt ap-
pears asking whether or not data
should be saved when Rehm soft-
ware is exited, when a new program
is loaded or when a different user
logs on.
Fig. 5-26 System Settings / Import/Export,
Export Format
Export Format
The standard system only supports
the specific CAB format which is
also supported by the operating sys-
tem.
CAB files can be opened directly
with the Explorer and decom-
pressed. If this is not possible, the
function can be initiated with the fol-
lowing commands: “Start->Run-
>Regsvr32 cabview.dll”.