OperationInstruction_Vsision XP.pdf - 第110页

Page 102 V ISION XP+ V AC 5 Software 5.4 The Data Menu Operating Instructions V ersion 1.5 5.4.4 The Scheduler (optional) Programs can be loaded and start ed on specified days at specified times with the schedu ler . Fig…

100%1 / 214
VISION XP+ VAC Page 101
5 Software
5.4 The Data Menu
Operating Instructions
Version 1.5
5.4.3 Data Management
Fig. 5-37 The “Program Management” Menu Function
Programs and products (optional) which have been saved to memory are
displayed in this window.
Each product is linked to a program, which is displayed in the program
column. In order to link the product to another program, double click the
program and select another program from the list which then appears.
Products and programs can be deleted as well.
Export:
The “Export” button is used to create a CSV file “programs.csv” in the pro-
gram directory. The file contains the parameters for all programs and may
be imported into Excel directly.
Attention: Products and programs will be permanently deleted!
Page 102 VISION XP+ VAC
5 Software
5.4 The Data Menu
Operating Instructions
Version 1.5
5.4.4 The Scheduler (optional)
Programs can be loaded and started on specified days at specified times
with the scheduler.
Fig. 5-38 The Scheduler
Proceed as follows in order to create a schedule for a program:
1. Select a day.
2. Set a time.
Up to three actions can be executed per day.
3. Select the program to be used.
4. Select a mode.
Continuous: each selected day throughout the year (e.g. every
Monday).
Off: The selected program is not active.
One-time only: on the next selected day (e.g. next Tuesday).
5. These entries must be repeated for each day of the week in order to fill
out the schedule.
6. The Exceptions function accommodates additional scheduling tasks,
e.g. for holidays or high priority jobs.
VISION XP+ VAC Page 103
5 Software
5.4 The Data Menu
Operating Instructions
Version 1.5
5.4.5 Machine Parameters
This function may only be utilized by service technicians from
Rehm Thermal Systems, or in accordance with specially issued instructions.
The values of machine parameters are indicated in the masks blue and they
are independent of the product.