HS50_advance_level 2.pdf - 第193页

Stud ent Gu ide HS-5 0 Adva nced II 07/2 002 Ed ition 7 X- Axis 35  0 HFKDQLFDO VHWWLQ JV  %HOW 7 HQVLRQRI;$[LV  0HDVXULQJ'DW DDQG$LGLQJ7 RROV  0HDVXULQJ6HTXHQFH ➠ Move the x-sli de a…

100%1 / 431
07/2002 Edition Student Guide HS-50 Advanced II
7 X-Axis
34
DANGER POWERFUL MAGNETIC FIELD
Always follow the special safety instructions when working in the vicinity of powerful magnetic
fields.
Loosen two M3 x 8 hexagon socket-head screws (item 2 in Fig. 7.5 - 8) to remove the incre-
mental encoder for the X-axis (item 1 in Fig. 7.5 - 8
).
Loosen the eleven M2.5 x 5 hexagon socket-head screws (item 3 in Fig. 7.5 - 8) with washers.
Move the head mount (item 6 in Fig. 7.5 - 8) across as far as the elastomeric spring (item 7 in
Fig. 7.5 - 8
) in order to prevent any damage to proximity switches B1 and B2 (item 5 in Fig. 7.5
- 8).
Remove the scale (item 4 in Fig. 7.5 - 8).
 ,QVWDOOLQJWKH;D[LVVFDOH
Carefully insert the scale.
CAUTION
Do not touch the incremental tracks with bare fingers.
Loosely tighten the eleven M2.5 x 5 hexagon socket-head screws with washer.
Push the scale along the bars as far as the stop (item A in Fig. 7.5 - 8)
Tighten the M2.5 x 5 hexagon socket-head screws.
Use the feeler gauge to set the 0.4 mm gap between the incremental encoder and scale.
Use the two M3x8 hexagon socket-head screws (item 2 in Fig. 7.5 - 8) to fix the incremental
encoder (item 1 in Fig. 7.5 - 8
) to the X-axis.
 6HWWLQJV
Set and calibrate the collect&place head and gantry axes using the SITEST program.
Student Guide HS-50 Advanced II 07/2002 Edition
7 X-Axis
35
 0HFKDQLFDOVHWWLQJV
 %HOW7HQVLRQRI;$[LV
 0HDVXULQJ'DWDDQG$LGLQJ7RROV
 0HDVXULQJ6HTXHQFH
Move the x-slide against the stop on the motor side.
Measure the belt tension on the side of the placement head.
Center the measuring pin of the belt tension measuring device, 208 mm away from the
deflection pulley of the open ended toothed belt, as close as possible to the belt.
%HOW%UDQGQHZ %HOW6KUXQNDIWHUDSSUR[
KRXUVRIRSHUDWLRQ
toothed belt to be measured frequency (Hz) frequency (Hz)
at the x-axis (open ended) 53 Hz +1 / -3 Hz 53 Hz +1 / -3 Hz
07/2002 Edition Student Guide HS-50 Advanced II
7 X-Axis
36
.(<
(A) Detail, zoom
(1) Chuck key
(2) Chuck key
(3) Head screw M4 x 35 to tension the toothed belt
(4) Head mounting
(5) Toothed belt of x-axis
(6) Deflection unit X
(7) Spacer disk with Benzing-U-Clip
(8) Head screw M4 x 5
(9) Synchronizing disk, short
(10) Synchronizing disk, long
A
A
1
8
7
9
10
2
3
1
2
4
5
6