Stud ent Gu ide HS-5 0 Adva nced II 07/2 002 Ed ition 3 Power Supply 57  3DUWV  5HPRYLQJ (/5RU(/5 DANGER Switc h off the plac ement sy stem and disconn ect from the po wer suppl y (see section s 3.3…

100%1 / 431
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
56
Detach the cable lugs (1) from the terminal links one by one and identify the terminal wires with
self-adhesive labels.
Loosen the M6 hexagon head screw (2) and remove the retaining ring (3).
Remove the rectifier (4).
Remove residue of heat transfer compound from the surfaces of the unit.
 )LWWLQJUHFWLILHU9WR9DQG9
Apply heat transfer compound to the "metal side" of the rectifier.
Fit the rectifier (4) and retaining ring (3).
Fix the rectifier in place with the M6 hexagon head screw (2).
Attach the cable lugs, ensuring that the polarity is correct.
Switch the placement system on and start it up.
Measure the voltages as per the table "Voltages at rectifiers V1 - V8" on page 3 - 16.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HPRYLQJHOHFWURQLFORDGGLVFRQQHFWLQJUHOD\(/5RU(/5
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Digital multimeter
HS-50 detailed circuit diagrams
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
57
 3DUWV
 5HPRYLQJ(/5RU(/5
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
Use the screwdriver to push back the yellow (1) terminal link slightly.
Pull the terminal wires out one by one and identify with adhesive labels.
Use the screwdriver to press down the two locking lugs (2) on the back and remove ELR1 (3)
or ELR2 from the top-hat rail.
 )LWWLQJ(/5RU(/5
Place ERL1 and/or ERL2 on the top-hat rail and snap into place.
Check that it is firmly seated.
Connect the marked terminal wires. Ensure that they are firmly attached.
3RVLWLRQ 'HVLJQDWLRQ ,WHPQXPEHU
ELR1, ELR2 (Fig. 5.8.2) Board ARL TC 31034-01 00341835-01
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
58
Switch the placement system on and start it up.
Use the digital voltmeter to measure the voltages.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJHOHFWURO\WLFFDSDFLWRU&
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Set of Phillips screwdrivers
Self-adhesive labels
Digital multimeter
HS-50 detailed circuit diagrams
 3DUWV
 5HPRYLQJWKHHOHFWURO\WLFFDSDFLWRU
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
9ROWDJH %HWZHHQFRQWDFWV
Control voltage 9 - 10
24 VDC 11 - 10
230 VAC 1 - 3, 2 - 4
5 - 7, 6 - 8
3RVLWLRQ 'HVLJQDWLRQ ,WHPQXPEHU
C1 Electrolytic capacitor 33000 µF/63 V 00342399-01