07/2002 Editio n Student G uide HS -50 Advanc ed II 3 Power Sup ply 36  ➠ Use the screwd river to press dow n the locki ng lug (4) on the back of the motor circu it-brea ker . ➠ T ilt the motor ci rcuit-br eake r upward…

100%1 / 431
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
35
 3DUWV
PKZ2/3-pole/40 motor circuit-breaker, item number 00342494-01.
 5HPRYLQJPRWRUFLUFXLWEUHDNHU06
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
Remove the motor trip block (2)
(see Section 3.3.5
)
Loosen the clamping screws (3) on
the motor circuit breaker (1)
Remove the terminal wires one by one
and identify with adhesive labels
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
36
Use the screwdriver to press down the locking lug (4) on the back of the motor circuit-breaker.
Tilt the motor circuit-breaker upwards and pull forward to remove.
 )LWWLQJPRWRUFLUFXLWEUHDNHU06
Attach the motor circuit breaker
at position 1 on the top hat rail
Push down lightly on the motor circuit-
breaker until it snaps into place
Check that the motor circuit-breaker
is seated firmly
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
37
Connect up the terminal wires.
Insert the motor trip block (see section 3.3.5.4 on page 3 - 33).
Use the digital voltmeter to measure the supply voltages at terminals L1, L2, L3 or T1, T2 and
T3.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJFRQWDFWRU6=
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Self-adhesive labels
Digital multimeter
HS-50 detailed circuit diagrams
 3DUWV
SIRIUS 3RT10/24 VDC contactor, size S2, item number 00341201-01
 5HPRYLQJFRQWDFWRU6=
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).