HS50_advance_level 2.pdf - 第342页

07/2002 Editio n Student G uide HS -50 Advanc ed II 11 DP-Axis 20 NOTE If the P-g ain has b een adj usted co rrectl y , a po sitionin g time of 48 ms + 5  ms will be re ached .  (See )  3*DL QWRR+L JK   NOTE I…

100%1 / 431
Student Guide HS-50 Advanced II 07/2002 Edition
11 DP-Axis
19
 $GMXVWPHQWRI3*DLQ
6,7(67 
Select "C&P Heads" ==> "Select head" ==>
"Axis functions" ==> "Select dp - axis" ==> "Adjust P-gain".
With the help of the ÇÆ arrow buttons, set a distance of 3600 dgts.
If necessary, press the START button.
2VFLOORVFRSH6HWWLQJV 


Adjust the P-gain, avoiding any oscillation of the current curve.
&KDQQHO 6LJQDO &RXSOLQJ <'HIOHFWLRQ 7ULJJHU ;'HIOHFWLRQ
CH1 Vnominal DC 2.0 V/ DIV
CH 4
negative
10% pre
10 ms/ DIV
CH2 deviat. of pos DC 0.5 V/ DIV
CH3 actual current DC 2.0 V/ DIV
CH4 end signal DC 5.0 V/ DIV
07/2002 Edition Student Guide HS-50 Advanced II
11 DP-Axis
20
NOTE
If the P-gain has been adjusted correctly, a positioning time of 48 ms + 5ms will be reached.
(See ) 
3*DLQWRR+LJK 

NOTE
If the P-gain is set too high, the actual current will oscillate 
&KDQQHO 6LJQDO &RXSOLQJ <'HIOHFWLRQ 7ULJJHU ;'HIOHFWLRQ
CH1 Vnominal DC 2.0 V/ DIV
CH 1
negative
10% pre
10 ms/ DIV
CH2 deviat. of pos DC 1.0 V/ DIV
CH3 actual current DC 5.0 V/ DIV
CH 4 end signal DC 5.0 V/ DIV
Student Guide HS-50 Advanced II 07/2002 Edition
11 DP-Axis
21
3$QWHLO]XQLHGULJ 


