HS50_advance_level 2.pdf - 第92页

07/2002 Editio n Student G uide HS -50 Advanc ed II 3 Power Sup ply 54  ➠ Loose n the M5 fil lister head sc rews (1). ➠ Remove the ret aini ng rings (2). ➠ Remove the perspex cover (3) ➠ Loose n the termi nal wir e scre…

100%1 / 431
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
53
CAUTION
Ensure that the cables do not become trapped, otherwise the insulation will be damaged.
Fix the fixing bar in place.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJUHFWLILHU9DQG9
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Open-ended spanner or socket spanner, size 8
Self-adhesive labels
Heat transfer compound
Digital multimeter
HS-50 detailed circuit diagrams
 3DUWV
V1, V7 rectifier S101-B6U-160-08, item number 00341246-01
 5HPRYLQJWKHUHFWLILHU
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
54
Loosen the M5 fillister head screws (1).
Remove the retaining rings (2).
Remove the perspex cover (3)
Loosen the terminal wire screw connections (4) one by one and identify with self-adhesive la-
bels.
Loosen the hexagon screw bolts (5).
Loosen the M5 nuts (6).
Remove the lock washer (7).
Remove the rectifier (8).
Remove residue of heat transfer compound from the surfaces of the unit.
 )LWWLQJUHFWLILHU9DQG9
Apply heat transfer compound to the "metal side" of the rectifier.
Fit the rectifier (8).
Fit the lock washer (7) and fix to the rectifier with an M5 hexagon nut (6).
Attach the hexagon screw bolts (5).
Connect the terminal wires (4) (ensure that the polarity is correct).
Switch the placement system on and start it up.
Use the digital voltmeter to measure the voltages shown in the "Voltages at rectifiers V1 - V8"
table on page 3 - 16
.
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
55
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
Fix the perspex panel to the rectifier.
PLEASE NOTE:
Do not overtighten the M5 fillister head screws, otherwise the panel might break.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJUHFWLILHU99999RU9
 7RROVDQGHTXLSPHQW
Open-ended spanner or socket spanner, size 10
–Pliers
Self-adhesive labels
Heat transfer compound
Digital multimeter
HS-50 detailed circuit diagrams
 3DUWV
 5HPRYLQJUHFWLILHU9WR9DQG9
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
3RVLWLRQ 'HVLJQDWLRQ ,WHPQXPEHU
V2 Rectifier S61-B2U 28-02 00341244-01
V3 - V6, V8 Rectifier S63-B6U 28-02 00341245-01