HS50_advance_level 2.pdf - 第96页

07/2002 Editio n Student G uide HS -50 Advanc ed II 3 Power Sup ply 58 ➠ Switch th e placeme nt system o n and s tart it up. ➠ Use t he dig it al vo ltmet er to m easur e th e volt age s. ➠ Complete th e servi cing wor k…

100%1 / 431
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
57
 3DUWV
 5HPRYLQJ(/5RU(/5
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
Use the screwdriver to push back the yellow (1) terminal link slightly.
Pull the terminal wires out one by one and identify with adhesive labels.
Use the screwdriver to press down the two locking lugs (2) on the back and remove ELR1 (3)
or ELR2 from the top-hat rail.
 )LWWLQJ(/5RU(/5
Place ERL1 and/or ERL2 on the top-hat rail and snap into place.
Check that it is firmly seated.
Connect the marked terminal wires. Ensure that they are firmly attached.
3RVLWLRQ 'HVLJQDWLRQ ,WHPQXPEHU
ELR1, ELR2 (Fig. 5.8.2) Board ARL TC 31034-01 00341835-01
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
58
Switch the placement system on and start it up.
Use the digital voltmeter to measure the voltages.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJHOHFWURO\WLFFDSDFLWRU&
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Set of Phillips screwdrivers
Self-adhesive labels
Digital multimeter
HS-50 detailed circuit diagrams
 3DUWV
 5HPRYLQJWKHHOHFWURO\WLFFDSDFLWRU
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
9ROWDJH %HWZHHQFRQWDFWV
Control voltage 9 - 10
24 VDC 11 - 10
230 VAC 1 - 3, 2 - 4
5 - 7, 6 - 8
3RVLWLRQ 'HVLJQDWLRQ ,WHPQXPEHU
C1 Electrolytic capacitor 33000 µF/63 V 00342399-01
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
59
Loosen the screws (1) and identify the polarity of the terminal wires with adhesive labels.
Loosen the Phillips screw (2) and lift the capacitor (3) out of the clamping ring (4).
 )LWWLQJWKHHOHFWURO\WLFFDSDFLWRU
Fit the capacitor and clamp in place.
Ensure that the polarity is correct when you connect the terminal wires.
Switch the placement system on.
Use the digital voltmeter to measure 52 VDC at the capacitor.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJPDLQSRZHUILOWHU=
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Open-ended spanner, size 8 and socket spanner, size 10
Self-adhesive labels