HS50_advance_level 2.pdf - 第35页
Stud ent Gu ide HS-5 0 Adva nced II 07/2 002 Ed ition 2 Ov erview Blo ck Diagrams 7 3RZ H U6 XSS O\ The Powe r supply basica lly c an be cla ssified as the sy stem th at takes in the incom ing three -phas e supply a…

07/2002 Edition Student Guide HS-50 Advanced II
2 Overview Block Diagrams
6
0HFKDQLFV
The mechanical structure of the machine is obviously the physical build of the machine.
Param-eters within the mechanics, such as belt tensions, have a direct effect on the control sys-
tem and so will be consider in the future with is section.
Mechanics
PCB Transport
Component table
C&P Head
Gantry
Tape Cutter

Student Guide HS-50 Advanced II 07/2002 Edition
2 Overview Block Diagrams
7
3RZHU6XSSO\
The Power supply basically can be classified as the system that takes in the incoming three-phase
supply and then controls, transforms, rectifies and distributes the voltage to the individual mod-
ules.
Power Supply Unit
External Supply
Europe: 3 x 400V
Americas: 3 x 204V
Other: 3 x 380V or
3 x 415V
Control Unit
Servo Unit
Transport System
Component Table
Station
Computer +
Moni tors
Z/DP Axes
Star Axes
X/Y Axes
Control Unit
Feeder Supply
Belt Drives
Lifting Tables
Service Plug

07/2002 Edition Student Guide HS-50 Advanced II
2 Overview Block Diagrams
8
3QHXPDWLF6XSSO\
The Pneumatic system firstly controls and regulates the incoming air supply. The system then dis-
tributes the air around the machine. The air is used to provide the driving force for items within
the machine and also to generate vacuum via the Venturi systems.
Pneumatic Unit
5,3 bar supply
Bulk Case 4
Bulk Case 3
Bulk Case 2
Bulk Case 1
Component
Table 4
Component
Table 3
Component
Table 2
Component
Table 1
Stopper
BB2 left
Stopper
BB2 right
Stopper
BB1 left
Stopper
BB1 right
Cutter 4
Cutter 3
Cutter 2
Cutter 1
Gantry
Distributor 4
Gantry
Distributor 3
Gantry
Distributor 2
Gantry
Distributor 1
C&P Head 4
C&P Head 3
C&P Head 2
C&P Head 1
Changer 2B
Nozzle
Changer 2A
Changer 1B
Nozzle
Changer 1A
Changer 3B
Nozzle
Changer 3A
Changer 4B
Nozzle
Changer 4A
2,5 bar supply
Main Supply 6,5 - 8 bar