HS50_advance_level 2.pdf - 第75页

Stud ent Gu ide HS-5 0 Adva nced II 07/2 002 Ed ition 3 Power Supply 37 ➠ Connect u p the term inal wir es. ➠ Insert t he motor tri p block (see sec tion 3.3.5.4 on page 3 - 33 ). ➠ Use the di gital voltm eter t o measur…

100%1 / 431
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
36
Use the screwdriver to press down the locking lug (4) on the back of the motor circuit-breaker.
Tilt the motor circuit-breaker upwards and pull forward to remove.
 )LWWLQJPRWRUFLUFXLWEUHDNHU06
Attach the motor circuit breaker
at position 1 on the top hat rail
Push down lightly on the motor circuit-
breaker until it snaps into place
Check that the motor circuit-breaker
is seated firmly
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
37
Connect up the terminal wires.
Insert the motor trip block (see section 3.3.5.4 on page 3 - 33).
Use the digital voltmeter to measure the supply voltages at terminals L1, L2, L3 or T1, T2 and
T3.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJFRQWDFWRU6=
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Self-adhesive labels
Digital multimeter
HS-50 detailed circuit diagrams
 3DUWV
SIRIUS 3RT10/24 VDC contactor, size S2, item number 00341201-01
 5HPRYLQJFRQWDFWRU6=
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
38
Remove auxiliary contact blocks K11, K12 and K14 from contactor SZ1.
To do this, push the lug (3) on the top of the auxiliary contact block towards the front panel and
hold in place.
Raise the auxiliary contact blocks (1) and remove from the slots.
Loosen the clamping screws (4) on contactor SZ1.
Pull the terminal wires out one by one and identify with adhesive labels.
Use the screwdriver to press down the locking lug (5) on the back of the contactor.
Tilt the contactor upwards and detach from the top-hat rail.
 )LWWLQJFRQWDFWRU6=
Attach the contactor to the top edge of the top-hat rail.
Push down on the contactor until it snaps into place.
Check that it is firmly seated.
Connect up the terminal wires.
Insert auxiliary contact blocks K11, K12 and K14 from the top and snap into place.
Switch the placement system on.
Test the 24 VDC control voltage between terminals A1 and A2.
Test the supply voltage between terminals L1, L2, L3 and T1, T2 and T3.
Complete the servicing work as described in 3.3.3 on page 3 - 29.