Stud ent Gu ide HS-5 0 Adva nced II 07/2 002 Ed ition 3 Power Supply 55 DANGER Switc h off the plac ement sy stem and disconn ect from the po wer suppl y (see section s 3.3. 1 and 3.3.2 ).  ➠ Fix the pe rspe x panel to …

100%1 / 431
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
54
Loosen the M5 fillister head screws (1).
Remove the retaining rings (2).
Remove the perspex cover (3)
Loosen the terminal wire screw connections (4) one by one and identify with self-adhesive la-
bels.
Loosen the hexagon screw bolts (5).
Loosen the M5 nuts (6).
Remove the lock washer (7).
Remove the rectifier (8).
Remove residue of heat transfer compound from the surfaces of the unit.
 )LWWLQJUHFWLILHU9DQG9
Apply heat transfer compound to the "metal side" of the rectifier.
Fit the rectifier (8).
Fit the lock washer (7) and fix to the rectifier with an M5 hexagon nut (6).
Attach the hexagon screw bolts (5).
Connect the terminal wires (4) (ensure that the polarity is correct).
Switch the placement system on and start it up.
Use the digital voltmeter to measure the voltages shown in the "Voltages at rectifiers V1 - V8"
table on page 3 - 16
.
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
55
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
Fix the perspex panel to the rectifier.
PLEASE NOTE:
Do not overtighten the M5 fillister head screws, otherwise the panel might break.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HSODFLQJUHFWLILHU99999RU9
 7RROVDQGHTXLSPHQW
Open-ended spanner or socket spanner, size 10
–Pliers
Self-adhesive labels
Heat transfer compound
Digital multimeter
HS-50 detailed circuit diagrams
 3DUWV
 5HPRYLQJUHFWLILHU9WR9DQG9
DANGER Switch off the placement system and disconnect from the power
supply (see sections 3.3.1 and 3.3.2).
3RVLWLRQ 'HVLJQDWLRQ ,WHPQXPEHU
V2 Rectifier S61-B2U 28-02 00341244-01
V3 - V6, V8 Rectifier S63-B6U 28-02 00341245-01
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
56
Detach the cable lugs (1) from the terminal links one by one and identify the terminal wires with
self-adhesive labels.
Loosen the M6 hexagon head screw (2) and remove the retaining ring (3).
Remove the rectifier (4).
Remove residue of heat transfer compound from the surfaces of the unit.
 )LWWLQJUHFWLILHU9WR9DQG9
Apply heat transfer compound to the "metal side" of the rectifier.
Fit the rectifier (4) and retaining ring (3).
Fix the rectifier in place with the M6 hexagon head screw (2).
Attach the cable lugs, ensuring that the polarity is correct.
Switch the placement system on and start it up.
Measure the voltages as per the table "Voltages at rectifiers V1 - V8" on page 3 - 16.
Complete the servicing work as described in 3.3.3 on page 3 - 29.
 5HPRYLQJHOHFWURQLFORDGGLVFRQQHFWLQJUHOD\(/5RU(/5
 7RROVDQGHTXLSPHQW
Set of slotted-head screwdrivers
Digital multimeter
HS-50 detailed circuit diagrams