07/2002 Editio n Student G uide HS -50 Advanc ed II 3 Power Sup ply 18  6HFRQGDU\VLGHRIWUDQVIRUPH U7  

100%1 / 431
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
17
RISK OF DEATH BY ELECTRIC SHOCK
➠ Switch the placement system off at the main switch.
➠ Disconnect the placement system from the power supply.
➠ Wait approximately 1 minute until the residual voltages have dropped to a safe level (electro-
lytic capacitor C1).
➠ Attach the perspex safety panel and fix in place with the M5 fillister head screws.
CAUTION
Do not overtighten the fillister head screws. The perspex panel might break.
 0HDVXULQJYROWDJHVDWWUDQVIRUPHU7
3ULPDU\VLGHRIWUDQVIRUPHU7
The transformer can be connected to the following main power supplies:
3 x 230 VAC for the "on-board electrical system" is drawn at terminals 1U5, 1V5 and 1W5. This is
used to supply the PC, the monitor and the lifting table motors.
Voltage Terminals
3 x 204 VAC (U. S. A.) ± 5 %, 50/60 Hz 1U6, 1V6, 1W6
3 x 230 VAC ± 5 %, 50/60 Hz 1U5, 1V5, 1W5
3 x 380 VAC ± 5 %, 50/60 Hz 1U4, 1V4, 1W4
3 x 400 VAC (Europe) ± 5 %, 50/60 Hz 1U3, 1V3, 1W3
3 x 415 VAC ± 5 %, 50/60 Hz 1U1, 1V1, 1W1
07/2002 Edition Student Guide HS-50 Advanced II
3 Power Supply
18
6HFRQGDU\VLGHRIWUDQVIRUPHU7
Student Guide HS-50 Advanced II 07/2002 Edition
3 Power Supply
19
Transformer T1 supplies the following voltages on the secondary side:
– 3 x 140 VAC
–3 x 5 VAC
–3 x 24 VAC
–3 x 25 VAC
–3 x 6 VAC
–3 x 38 VAC
–3 x 20 VAC
 0HDVXULQJYROWDJHVDWWKHPDLQSRZHUILOWHU=DQGHOHFWURO\WLFFDSDFLWRU&
Z1 Main power filter for 36 A 3-phase systems
E Input terminals of main power filter Z1
A Output terminals of main power filter Z1
C1 33000 µF / 63 V electrolytic capacitor
R1 Discharge resistor
0RGXOH 7HUPLQDO 9ROWDJHV
Main power filter Z1 L1, L2, L3 3 x 204 VAC / 3 x 230 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
Electrolytic capacitor C1 + / - 52 VDC
R1
C1
Z1
+
-
L1
L2
PE
L3
AE
PE
L3
L2
L1