Stud ent Gu ide HS-5 0 Adva nced II 07/2 002 Ed ition 11 DP-Axis 15 .(<WRILJ  TDS 120 A2.5Z = Serv o board z-axis  TDS 120 / 1D = Ser vo boar d dp - axis  TDS 120 = Pin configur ation  LED: Ready for…

100%1 / 431
07/2002 Edition Student Guide HS-50 Advanced II
11 DP-Axis
14
 $[LVG\QDPLFV
NOTE:
All SITEST functions are explained by the use of gantry 1
 7RROVDQG7HVW$LGV
2 or 4 channel storage oscilloscope.
SIPLACE axis test box.
–SITEST software.
NOTE
The machine must have reached its operating temperature before you begin to adjust the axes.
Therefore, make sure to switch it on, at least 30 minutes before you begin to work. 
 6HUYR%RDUG+HDG$[HV+6

Student Guide HS-50 Advanced II 07/2002 Edition
11 DP-Axis
15
.(<WRILJ
TDS 120 A2.5Z = Servo board z-axis 
TDS 120 / 1D = Servo board dp - axis 
TDS 120 = Pin configuration 
LED: Ready for operation 
LED: Enable output stage 
LED: Effective current limit 
LED: Error 
Potentiometer: Tacho 
Potentiometer: P-Amplification 

.(<
(1) LED: Ready for operation
(2) LED: Enable output stage
(3) LED: I
RMS
limit
(4) LED: Error

MP1 = Nominal current "I-S (U)" 
MP2 = Nominal current "I-S (W)" 
MP3 = Actual current "I-ist (U)" 
MP4 = Actual current "I-ist (W)" 

Ns Speed setpoint value
Ie Setpoint value, power input
Ta Tacho (real tacho voltage)
Is Nominal current (speed controller output)
IA Motor manipulated variable
(speed controller output)
li Actual current
Ss Sensor stop signal
0V Amplifier electronic GND
MP5 = "U-nominal (U)"
MP6 = "U-nominal (W)"
MP7 = Free
MP8 = Reference potential "0V"
07/2002 Edition Student Guide HS-50 Advanced II
11 DP-Axis
16
 2YHUYLHZRI$[HV&RQWURO&DUGV+6
type of axis and gantry number
adress of axis
'3 '3
'3
'3
CE = Counting error
0 = Zero pulse
ED = End signal
BE = General error, module error
IN = Initialized
ON = Servo ON
(A) Axis enable switch
(1) Servo ON
(2) Servo OFF