CP-7-series Verification System Instruction manual(2.0E).pdf - 第112页

13. Offline Changeovers Edition 2.0 101 CP-7-series V erification System Instruction Manual 5. Use Handy T erminal to read the unit ID attached to the device table. PDT -3100’s Unit ID Reading Screen Handy Scanner ’s Uni…

100%1 / 131
13. Offline Changeovers
Edition 2.0 100 CP-7-series Verification System Instruction Manual
4. At Fujitrax Verifier, select whether the device table Verification operation was based on
the current production recipe or the next production recipe. (If the next production
recipe is not selected, only the current production recipe name displays.)
PDT-3100’s Pallet Supply Selection Screen
Handy Scanner’s Pallet Supply Selection Screen
ENTER/QUIT:
[PALETTE SUPPLY]
Fore :Recipe1
Pre :Recipe2
▼▲
CP7V0026a
13. Offline Changeovers
Edition 2.0 101 CP-7-series Verification System Instruction Manual
5. Use Handy Terminal to read the unit ID attached to the device table.
PDT-3100’s Unit ID Reading Screen
Handy Scanner’s Unit ID Reading Screen
ENTER/QUIT:
[PALETTE SUPPLY]
Recipe: Recipe1
READ UNIT ID LABEL
UNIT ID=v
CP7V0027a
13. Offline Changeovers
Edition 2.0 102 CP-7-series Verification System Instruction Manual
6. Use Handy Terminal to read barcode which indicates the stage number, and then specify
the stage where the pallet is to be mounted.
PDT-3100’s Unit Supply Stage Selection Screen
Handy Scanner’s Unit Supply Stage Selection Screen
7. The machine checks with Fujitrax Verifier to see if the pallet has been verified
(Verification operation), and the check result displays at Handy Terminal.
PDT-3100’s Unit Verification Complete Screen PDT-3100’s Unit Verification Error Screen
NEXT: /QUIT:
[PALETTE SUPPLY]
Recipe: Recipe1
UNIT ID: Table1
STAGE NO.:STAGE1
Verifier ANS.:OK
CP7V0029a
RESET: /QUIT:
[PALETTE SUPPLY]
Recipe: Recipe1
UNIT ID: Table1
STAGE NO.:STAGE1
Verifier ANS.:NG
ENTER/QUIT:
[PALETTE SUPPLY]
Recipe: Recipe1
UNIT ID: Table1
READ STAGE NO. LABEL
STAGE NO.=v
CP7V0028a