CP-7-series Verification System Instruction manual(2.0E).pdf - 第80页

10. Using the DC AUTO Mode Edition 2.0 69 CP-7-series V erification System Instruction Manual 10..4.1.5 Check Against Fujitrax V erifier Database • The feeder/reel combination data r ead by the Fujitrax V erifier is chec…

100%1 / 131
10. Using the DC AUTO Mode
Edition 2.0 68 CP-7-series Verification System Instruction Manual
10.4 DC AUTO Mode Procedure 2
10.4.1 Operation Flowchart
When automatic operation begins following a device check, the feeder ID is read first,
then the feeder / reel combination information and other device information such as the
“remaining parts count”, etc., is downloaded from Fujitrax Verifier.
10.4.1.1 Recipe Switching
The recipe is switched.
10.4.1.2 Device Check
Device check is performed (see following pages for details).
An “Unread FIDL” status displays at the device check screen after a device check is
completed for a slot.
The “Unread FIDL” status changes to a “Parts Present” status following Fujitrax
Verifier verification at slots where feeder ID reading is completed without error.
10.4.1.3 Automatic Operation Start
Automatic operation begins.
10.4.1.4 Feeder ID Reading
The camera at ST1 reads the feeder IDs affixed to each feeder.
Feeder ID reading occurs only at slots where an “Unread FIDL” status exists.
The “Unread FIDL” status changes to a “Unread HOST” status at slots where
feeder ID reading is completed without error.
10. Using the DC AUTO Mode
Edition 2.0 69 CP-7-series Verification System Instruction Manual
10..4.1.5 Check Against Fujitrax Verifier Database
The feeder/reel combination data read by the Fujitrax Verifier is checked against
the feeder/reel combination data in the Fujitrax Verifier database to see if it
matches.
“Remaining parts count” information for each reel is downloaded from Fujitrax
Verifier.
10.4.1.6 Production Start
Production is started automatically.
10.4.1.7 Part Supply
Parts are supplied.
10.4.2 Device Check Flowchart
10. Using the DC AUTO Mode
Edition 2.0 70 CP-7-series Verification System Instruction Manual
10.4.2.1 Device Check Start
A device check can be started in the following three ways.
I. By selecting [Device Check] at the machine control panel.
II. At the PDT-3100 [Main Menu], select [1. Verify Check], then press [Enter].
PDT-3100’s Main Menu
III. With the main menu displayed at the Handy Scanner dialog box, read the "1"
barcode, and select "1. VERIFY CHECK".
Handy Scanner’s Main Menu
ENTER
[MAIN MENU]
1. VERIFY CHECK
2. PRE VERIFY CHECK
3. SET VERIFY RECIPE
4. PALLET SUPPLY
5. TEST READ
SELECT NO.=v
▼▲
CP7V0005