CP-7-series Verification System Instruction manual(2.0E).pdf - 第128页

15. Explanation of Operation Screens Edition 2.0 117 CP-7-series V erification System Instruction Manual Screen Explanation 10 Indicates the Stage where barcode reading is to occur. 20 Switches the Stage where barcode re…

100%1 / 131
15. Explanation of Operation Screens
Edition 2.0 116 CP-7-series Verification System Instruction Manual
15.3 Feeder ID Reading Test Screen
Function
This screen is used to perform a test reading of the 2D code which is affixed to the feeder. As
this reading is only for test purposes, the reading results are lost when this screen is closed,
and those results are not used for part verification.
Input
Execute the [Maintenance] - [Maintenance for Each Machine] - [Feeder Check Read Test]
commands to display the test screen:
The [Feeder Check Reader Test] item displays at the [Maintenance]
- [Maintenance for Each Machine] - [Feeder Check Read Test] screen only if the
[Use Fujitrax Verifier] button is selected at the [Parts Administration System] screen.
Screen Access
15. Explanation of Operation Screens
Edition 2.0 117 CP-7-series Verification System Instruction Manual
Screen Explanation
16. PDT-3100 Setting Items
Edition 2.0 118 CP-7-series Verification System Instruction Manual
16. PDT-3100 Setting Items
16.1 Automatic Verification Subject Slot Selection Function
This function allows the PDT-3100 to select the slots where verification is to occur. Because the
slot numbers are determined automatically, there is no need to read or enter slot numbers.
16.1.1 Screen Access
At Handy Terminal’s [Main Menu], select [SET ENVIRONMENT] to display this setting
screen.
PDT-3100’s [Main Menu] Screen
When the setting screen displays, select the desired setting, then press [ENTER].
[FOLLOW OPERATIONS]: Mode in which the operator determines the verification
subject slots.
[FOLLOW DIRECTIONS]: Mode in which PDT-3100 automatically determines the
verification subject slots.
PDT-3100’s [SET ENVIRONMENT] Screen.
ENTER/QUIT:
[SET ENVIRONMENT]
1. FOLLOW OPERATIONS
2. FOLLOW DIRECTIONS
SELECT NO.=v
▼▲
CP7V0035a
ENTER
[MAIN MENU]
3. SET VERIFY RECIPE
4. PALLET SUPPLY
5. TEST READ
6. SET ENVIRONMENT
7. TRY COMMUNICATION
SELECT NO.=v
▼▲
CP7V0034