CP-7-series Verification System Instruction manual(2.0E).pdf - 第66页

9. Using The Normal V erification Mode Edition 2.0 55 CP-7-series V erification System Instruction Manual 9.4 Normal V erification Procedure 5 The normal verification mode is inoperative in this configuration because the…

100%1 / 131
9. Using The Normal Verification Mode
Edition 2.0 54 CP-7-series Verification System Instruction Manual
9.3.8 All LEDs ON at Stage to be Verified
LEDs for all slots to be verified at the current verify subject stage are on.
Data flow
The position where the feeder was set and the device comment read by Handy Terminal
is checked against the recipe to determine if the data matches.
CC
CC
PP
PP
77
77
1 1 aaaaa
1 2 bbbbb
2 1 ccccc
2 2 ddddd
Stage Slot Comment DIDFIDL
Stage Slot Comment
CP7V0017E
Production Program
Specifications:
Acquired Data:
(4) Comparison
Stage
Slot
Comment
Production Program
(1) Production Program Analysis
(2) Device Comment Readings
(3) Feeder Settings
9. Using The Normal Verification Mode
Edition 2.0 55 CP-7-series Verification System Instruction Manual
9.4 Normal Verification Procedure 5
The normal verification mode is inoperative in this configuration because the Handy Terminal
is not used. Only the quick verification mode is operative.
For details concerning the quick verification procedure for this configuration, refer to the
“Quick Verification Procedure 1” section.
9.5 Normal Verification Procedure 7
The normal verification mode is inoperative in this configuration because the Handy Terminal
is not used. Only the quick verification mode is operative.
For details concerning the quick verification procedure for this configuration, refer to the
“Quick Verification Procedure 3” section.
9.6 Normal Verification Procedure 8
9.6.1 Operation Flowchart
When automatic operation begins following a device check, the feeder ID is read first,
then the feeder / reel combination information and other device information such as the
“remaining parts count”, etc., is downloaded from Fujitrax Verifier.
9. Using The Normal Verification Mode
Edition 2.0 56 CP-7-series Verification System Instruction Manual
9.6.1.1 Recipe Switching
The recipe is switched.
9.6.1.2 Device Check
Device check is performed (see following pages for details).
An “Unread FIDL” status displays at the device check screen after a device check is
completed for a slot.
The “Unread FIDL” status changes to a “Parts Present” status following Fujitrax
Verifier verification at slots where feeder ID reading is completed without error.
9.6.1.3 Automatic Operation Start
Automatic operation begins.
9.6.1.4 Feeder ID Reading
The camera at ST1 reads the feeder IDs affixed to each feeder.
Feeder ID reading occurs only at slots where an “Unread FIDL” status exists.
The “Unread FIDL” status changes to a “Unread HOST” status at slots where
feeder ID reading is completed without error.
9.6.1.5 Check Against Fujitrax Verifier Database
The feeder/reel combination data read by the Fujitrax Verifier is checked against
the feeder/reel combination data in the Fujitrax Verifier database to see if it
matches.
“Remaining parts count” information for each reel is downloaded from Fujitrax
Verifier.
9.6.1.6 Production Start
Production is started automatically.
9.6.1.7 Part Supply
Parts are supplied.