CP-7-series Verification System Instruction manual(2.0E).pdf - 第88页

10. Using the DC AUTO Mode Edition 2.0 77 CP-7-series V erification System Instruction Manual Data flow (after automatic operation start) The FIDL which was r ead is used as a key to search the Fujitrax V erifier databas…

100%1 / 131
10. Using the DC AUTO Mode
Edition 2.0 76 CP-7-series Verification System Instruction Manual
Data flow (at verification)
The position where the feeder was set and the device comment read by Handy Terminal
is checked against the recipe to determine if the data matches.
CC
CC
PP
PP
77
77
Stage Slot Comment DIDFIDL
Stage Slot Comment
CP7V0018Ea
Production Program
Specifications:
Acquired Data:
(6) Comparison
1 1 aaaaa
1 2 bbbbb
2 1 ccccc
2 2 ddddd
Stage
Slot
Comment
Production Program
(1) Production Program Analysis
(2) DID Readings
(4) Device
comment is
returned as a
reply.
(5) Feeder Settings
(3) Device comment
is requested
based on the DID.
Fujitrax-Verifier
10. Using the DC AUTO Mode
Edition 2.0 77 CP-7-series Verification System Instruction Manual
Data flow (after automatic operation start)
The FIDL which was read is used as a key to search the Fujitrax Verifier database in
order to download the required information.
11. Using the FULL AUTO Mode
Edition 2.0 78 CP-7-series Verification System Instruction Manual
11. Using the FULL AUTO Mode
11.1 Operation Conditions
A “Use Fujitrax Verifier” setting must be specified at the [Parts Administration System] screen.
11.2 Preparations
11.2.1 Preparing Fujitrax Verifier
In the FULL AUTO mode, the feeder ID read system reads the feeder ID (FIDL), and the
device comment and DID are then obtained from Fujitrax Verifier based on the FIDL
that was read.
Therefore, the feeder (FIDL) and parts (DID, device comment) combination must be
registered in Fujitrax Verifier in advance.
11.2.2 Settings
At the [Maintenance] - [Configuration] - [Machine Function Settings]
- [Use Fujitrax Verifier] - [Parts Administration System] - [Fujitrax Verifier Settings] tab,
specify the FULLAUTO Quick Verification mode. For details, refer to chapter 6
“Settings” of this manual.
Note: Fujitrax Verifier is used in the FULL AUTO mode. Therefore, the FULL AUTO Quick Verify
mode is only operative when the "Use Fujitrax Verifier" setting are specified.
Fujitrax Verifier
Register the feeder / part combination
at Fujitrax Verifier in advance.
CP7V0055E
Handy