CP-7-series Verification System Instruction manual(2.0E).pdf - 第69页
9. Using The Normal V erification Mode Edition 2.0 58 CP-7-series V erification System Instruction Manual 9.6.2.1 Device Check Start • A device check can be started in the following three ways. I. By selecting [Device Ch…

9. Using The Normal Verification Mode
Edition 2.0 57 CP-7-series Verification System Instruction Manual
9.6.2 Device Check Flowchart
Device check start
Stage to be checked is determined
Slot to be checked is determined
Mismtch
No
No
No
To [1]
To [2]
Match
DID reading
ID which was acquired
is compared with recipe’s
device comment
Is a device
comment delimiter being used
in the DID?
: Operator tasks
: Machine processing
LED on at slot to be verified
Device comment is
extracted from the
DID.
Device comment
reading
Feeder is set
LED on at stage to be verified
Unshaded box
Shaded box
[1]
[2]
Yes
Yes
Yes
Device check completed
All device checks completed
at this stage?
Device checks completed
at both sides?

9. Using The Normal Verification Mode
Edition 2.0 58 CP-7-series Verification System Instruction Manual
9.6.2.1 Device Check Start
• A device check can be started in the following three ways.
I. By selecting [Device Check] at the machine control panel.
II. At the PDT-3100 [Main Menu], select [1. Verify Check], then press [Enter].
PDT-3100’s Main Menu
III. With the main menu displayed at the Handy Scanner dialog box, read the "1"
barcode, and select "1. VERIFY CHECK".
Handy Scanner’s Main Menu
ENTER
[MAIN MENU]
1. VERIFY CHECK
2. PRE VERIFY CHECK
3. SET VERIFY RECIPE
4. PALLET SUPPLY
5. TEST READ
SELECT NO.=v
▼▲
CP7V0005

9. Using The Normal Verification Mode
Edition 2.0 59 CP-7-series Verification System Instruction Manual
9.6.2.2 Determining the Stage to be Verified
• The stage to be verified can be determined in the following four ways.
I. If a feeder is set in the slot where an LED is on, the stage to be verified can
be determined by removing that feeder (the slot to be verified is also
determined at this time).
II. The stage number barcode affixed to the machine rear can be read to the
PDT-3100.
III. The stage to be verified can be selected from the stage selection screen at the
PDT-3100.
PDT-3100’s Stage Selection Screen
IV. With the “Input Stage No.” item displayed at the Handy Scanner dialog box,
use the scanner to read the Stage number barcode on the rear of the machine.
Handy Scanner’s Stage Selection Screen
Notes:
• The Verification operation must be performed for each stage.
• To perform a verification at Stage 2, for example, after Stage 1 has been selected, the
device check must be interrupted, and the verification must be started again.
• When using the Scanner, it is possible to return to the “Input Stage No.” step without
interrupting the device check. This is done by reading the “BACK” barcode.
ENTER/QUIT:
[VERIFY CHECK]
CP7V0006a
▲
SELECT START STAGE
1. STAGE1
2. STAGE2
SELECT STAGE NO.=v
▼▲