Safety Precautions
Page S-42 EJM9BE-SF-02N-24
Handling of the change cart switch unit
Be careful enough in handling the change cart switch unit drive because it weighs 21 k
g
; be sure to use
the switching cart when handling it.
While handling the change cart switch
unit drive, hold its handles with your both
hands.
Whenever attaching or detaching the
change cart switch unit drive, lock the two
stoppers on the switching cart.
When moving the change cart switch unit
drive, be sure to use the switching cart.
Switching cart
Change cart switch unit drive
Change cart switch unit drive
Switching cart
Handle
Switching cart stopper
NPM
Safety Precautions
EJM9BE-SF-02N-24 Page S-43
Handling of the change cart switch unit
Change cart switch unit drive
Drawer connector extension unit
N610098255AA_01
NOTICE
In carrying the drawer connector
extension unit, use both hands
because you may be injured if
dropping it.
NOTICE
The change cart switch unit should be stored in such a place as it will not be
bumped accidentally.
NPM
Safety Precautions
Page S-44 EJM9BE-SF-02N-24
Handling of the wired scanner
The handy scanner complies with IEC60825-1 Class 2 laser product.
Follow the rules below when using it.
1. The alignment beam (laser light) is emitted from the front window automatically.
Do not peer into the alignment beam. The eyes can be damaged.
When there are changes in subject,
the alignment beam is emitted automatically.
And then, when there are no change in it for
two seconds, the alignment beam stop
emission
2. Do not emit the alignment beam toward other peoples’ eyes.
The eyes can be damaged.
3. The alignment beam is emitted when it is disassembled. Do not disassemble it.
4. If you frequently mate/unmate the connector on the NPM main body,
communication trouble may occur. Keep the connector on the NPM main body
connected as far as possible.
The alignment beam
(Shape of irradiated subject)