CP43操作手册.pdf.pdf - 第207页
• Action of the Function Keys POSITION 1 : Press to set the first reading mark position in Proper data. POSITION 2 : Press to set the second reading mark position in Proper data. Z0 : Press to move the Z axis to Origin P…

• Action of the Function Keys
XC/YC : Press to measure the mark camera reading
position.
MARK : Press to measure the mark camera
resolution, tilt, and rotation.
WIDE : Press to measure the resolution, tilt, and
rotation of the wide view parts camera.
NARROW : Press to measure the resolution, tilt, and
rotation of the narrow view parts camera.
BRIGHT : Press to set the gain or offset level for the
parts cameras and the mark camera.
RETURN : Press to return to Page 530/000.
• First Status Area
CAMERA
• First Display Area
Mark Read Pos. XC: -403.18 mm YC: 296.27 mm
Mark Camera X: 18.5 um Y: 18.5 um
Standard Camera X: 80.0 um Y: 80.0 um
• Function Key Menu
Chapter 3 Description of Commands
To Page 531/100
To Page 531/200
To Page 531/300
To Page 531/400
To Page 531/500
To Page 530/000
Measuring Camera Proper Data
Part 3
3 – 81
CAMERA
Page
531 000
XC/YC MARK WIDE NARROW BRIGHT RETURN
Version 5.0
FCP IV-3 Operation

• Action of the Function Keys
POSITION 1: Press to set the first reading mark position in
Proper data.
POSITION 2: Press to set the second reading mark position in
Proper data.
Z0 : Press to move the Z axis to Origin Position Z in
Proper data.
SPEED : Press to set the inching speeds of the axes.
RETURN : Press to return to Page 531/000.
• START button
After setting POSITION 1, POSITION 2 and the mark camera
Proper data the message "Press START" will appear.
When the [START] button is pressed the camera mark reading
positions will be set into Mark Read Position X and Mark Read
Position Y.
For details refer to the FCP IV-3 Maintenance Manual.
• First Display Area
Mark Read Pos. XC: -403.18 mm YC: 296.27 mm
Mark Camera X: 18.5 um Y: 18.5 um
Standard Camera X: 80.0 um Y: 80.0 um
Coord1: Unset
Coord2: Unset
• Function Key Menu
Chapter 3 Description of Commands
To Page 531/000
Mark Camera Reading
Position/Power Setting
Part 3
3 – 82
XC/YC
Page
531 100
POSITION 1 POSITION 2 Z0 SPEED RETURN
Version 5.0
FCP IV-3 Operation

• Action of the Function Keys
RETURN : Press to return to Page 531/000
• START Button
When this button is pressed the X and Y coordinates will be set
and the camera position will be reset. Use this command after
measuring the camera XC/YC Proper data while the mark jig
remains directly below the Mark camera. Note that these
settings are machine Proper data settings and thus it is
necessary to transmit Proper data to the MCS 30 computer once
Proper data measurement is completed.
For details refer to the FCP IV-3 Maintenance Manual.
• First Display Area
Mark Read Pos. XC: -403.18 mm YC: 296.27 mm
Mark Camera X: 18.5 um Y: 18.5 um
Wide View X: 51.1 um Y: 52.0 um
Narrow View X: 23.5 um Y: 24.8 um
Delta X: 5 um
Delta Y: 8 um
Delta Q: 0.150 deg
Mark : Circle
• Function Key Menu
Chapter 3 Description of Commands
To Page 531/000
Measuring the Mark Camera
Position, Tilt
Part 3
3 – 83
MARK
Page
531 200
RETURN
Version 5.0
FCP IV-3 Operation