CP43操作手册.pdf.pdf - 第38页

Chapter 4 The Display Part 1 4.3 Second Display Area The second display area displays machine err or status and messages to the operator . (a) Current Machine Status Display Ar ea This area displays the curr ent status o…

100%1 / 364
Part 1 Chapter 4 The Display
4.2.2 Display When Not In Automatic Operation
(a) Information about all stations from one to seven is displayed.
ST1.N 1 D 35 Er ***
ST2.N 1 D 35 Er ***
ST3.N 1 D 35 Er ***
ST4.N 1 D 35 Er ***
ST5.N 1 D 35 Er 0
ST6.N 1 D 35 Er 0
ST7.N 1 D 35 Er 0
This is a display of the sequence and device numbers for every
station. “Er ***” means that vision processing has not yet been
completed. The “0” error code indicates that production has
finished under normal conditions. For further information on
error codes, refer to Part 6 of this manual.
Note: In Changeover mode and Device Change mode, when Device
Table 2 (81-160) is the original table, the device positions will
be displayed as 1-80. Note that when the next device is being
used, the machine will display the actual device number, (as
opposed to the device number which has been coded in the
program).
(b) The operation modes are displayed here in the same way they
are during automatic operation.
(c) Information about special operations is displayed here.
Seq. End Stop The machine has finished the board it was
processing when [S_STOP] was pressed.
(d) This display is the same as in the automatic operation display.
1 – 24Version 5.0
FCP IV-3 Operation
Chapter 4 The DisplayPart 1
4.3 Second Display Area
The second display area displays machine error status and messages to
the operator.
(a) Current Machine Status Display Area
This area displays the current status of the FCP IV-3.
Emergency Stop Under emergency conditions, this will be
displayed. When this happens, refer to (b),
Abnormal Operating Conditions Area.
Waiting for Reset SW The machine has stopped and is waiting for
the operator to restart it.
Press START Before the start of operation, the operator
must push the [START] button.
Machine Not Zero Set This item indicates that zero setting has not
yet been performed after the machine’s
power has been turned on. At this point the
[Position] command cannot be used.
Zero Set This item indicates that zero setting is being
carried out.
Ready The machine is operating and can receive
commands at this point.
Return Cam to Zero This displays if the cam axis is not at 0°.
Measuring Proper… The machine is now measuring Proper
data.
Emergency Stop
(a)
(c)
(d)
Waiting for Reset SW
Emergency Stop Pressed
D100 Resupply
Skip Nozzle
S CEIL
M ADL
L BG
Tape End
105 124
012
075
(b)
(e)
1 – 25Version 5.0
FCP IV-3 Operation
Part 1 Chapter 4 The Display
Operating HT… Operation is being conducted with the
Handy Terminal
Changing Over… In HELPS mode, changeover occurs
automatically and this message displays.
Producing… The machine is now placing parts.
Operating Loader A board is being loaded onto or unloaded
off the XY table
Waiting for PCB The machine has stopped and is waiting for
the next board to be loaded.
Waiting for NEXT The next machine has not yet requested a
new board, so this machine is waiting.
Turn off Power The machine will not recover without
turning off power.
(b) Error Display Area
If an error occurs a message will display here. For further information
about these messages, refer to Part 6 of this manual.
(c) Spare Device Status Display Area
In Device Change Mode, when the original table has been changed,
the table not in use acquires the status of spare device table.
d??? resupply The device table named in the message has
run short of parts. The original table has
been changed.
d??? check Parts could not be picked from the device
table named in the message. The original
table has been changed.
d??? unable to process Vision processing could not be carried out
on the parts coming from the device table
named in the message. The original table
has been changed.
1 – 26
Version 5.0
FCP IV-3 Operation