CP43操作手册.pdf.pdf - 第218页

• Action of the Function Keys SET : Press to set the relevant Pr oper data. RETURN : Press to return to Page 532/000. • First Status Area The relevant X0/Y0, YL/YL, XPCB/YPCB, Xmax/Ymax and Xmin/Ymin values are displayed…

100%1 / 364
Action of the Function Keys
X0/Y0 :Press to set the measurement results of the
reference point into Proper data.
XL/YL :Press to set the loading position
measurement results into Proper data.
XPCB/YPCB :Press to set the measurement results of board
check position into Proper data.
XMAX/YMAX :Press to set the measurement results of the
maximum movable area into Proper data.
XMIN/YMIN :Press to set the measurement results of the
mininum movable area into Proper data.
RETURN :Press to return to Page 530/000.
First Status Area
X/Y
First Display Area
Proper Data
Placing Pos. X0 : -49365 Mode : 1
Y0 : 32989 Servo counter
Loading Pos. XL : 170 X -049365
YL : -320 Y 0032989
PCB Check Pos. XPCB : 21 C 000000
XPCB : 23 D1 -482476
Max Limit Pos. Xmax : -6900 D2 -000001
Ymax : 340 Z -000390
Min Limit Pos. Xmin : 127 FQ 0005170
Ymin : 58 World (Zero)
Function Key Menu
Chapter 3 Description of Commands
To Page 532/100
To Page 532/100
To Page 532/100
To Page 532/100
To Page 532/100
To Page 530/000
Measuring Proper Data for
X, Y Axis
Part 3
3 – 92
X/Y
Page
532 000
X0/Y0 XL/YL XPCB/YPCB XMAX/YMAX XMIN/YMIN RETURN
Version 5.0
FCP IV-3 Operation
Action of the Function Keys
SET : Press to set the relevant Proper data.
RETURN : Press to return to Page 532/000.
First Status Area
The relevant X0/Y0, YL/YL, XPCB/YPCB, Xmax/Ymax and
Xmin/Ymin values are displayed here.
Second Display Area
If start conditions are fulfilled, the message “Press START”
flashes. Otherwise an error displays. Refer to Part 6 for details
on error codes.
Function Key Menu
Chapter 3 Description of Commands
To Page 532/000
Setting Proper Data for
X, Y Axis
Part 3
3 – 93
Page
532 100
SET RETURN
Version 5.0
FCP IV-3 Operation
Action of the Function Keys
PICKUP POS. :Press to set the standard parts pickup
position in Proper data.
ORIGIN :Press to set the D axes Resupply position in
Proper data.
MAX LIMIT :Press to set the D and Z axes' positive stroke
in Proper data.
MIN LIMIT :Press to set the D and Z axes' negative stroke
in Proper data.
RETURN :Press to return to Page 530/000.
First Display Area
Proper Data
D Axis PICKUP POS..T1 : 2474 Mode : 1
PICKUP POS. T2 : 58474 Servo Counter
D1 ORIGIN : 116208 X 000000
D2 ORIGIN : -390 Y 000000
Origin Pos. Z0 : 0 C 359880
Max Limit Pos. D1max : 500 D1 -482476
D2max : 492756 D2 -000001
Zmax : 1000 Z 000000
Min Limit Pos. D1min : -492531 FQ 000005
D2min : -500 World (Zero)
Zmin : -3000
For detailed information on Proper data measurement refer to the FCP IV-3
Maintenance Manual.
Function Key Menu
Chapter 3 Description of Commands
To Page 533/100
To Page 533/200
To Page 533/300
To Page 533/400
To Page 530/000
Setting Proper Data for
D1, D2, and Z Axis
Part 3
3 – 94
D1/D2/Z
Page
533 000
PICKUP POS. ORIGIN MAX LIMIT MIN LIMIT RETURN
Version 5.0
FCP IV-3 Operation