Chapter 2 Details of Proper Data Part 4 41: Cell Status Unit: Active: Passive $ # This is valid only for HELPS-compatible machines. This sets cell status. Unit: Unit cell Active: Active cell Passive: Passive cell The sta…

Chapter 2 Details of Proper DataPart 4
25: Conveyor Control Manu: Auto $#
This is valid only for HELPS-compatible machines. This selects whether or
not the conveyor width will be controlled automatically.
Manu: Manual conveyor adjustment
Auto: Automatic conveyor adjustment
The standard setting is "Manu."
26: Conveyor Adj. Limit 0.05 ~ 1.00 [mm] $#
This is valid only for HELPS-compatible machines. This sets the limit to
determine if fine adjustment of the conveyor width is required. Fine
adjustment is carried out if the difference between the current conveyor
width and the board width set in the program exceeds this limit. The
standard setting is 0.50 mm.
27: Conveyor Stop Offset 0.00 ~ 2.00 [mm] $#
This is valid only for HELPS-compatible machines. This sets the conveyor
stop offset during conveyor width adjustment. The standard setting is 0.30
mm.
28: Conveyor adj. Timer 0 ~ 120000 [msec] $#
This is valid only for HELPS-compatible machines. When performing
automatic conveyor width adjustment this value sets the amount of time
that elapses before a time-up error occurs. The standard setting is 60000
msec.
29: Width Max Limit 0.00 ~ 655.35 [mm] $❈
This sets the maximum conveyor width value. The standard setting is
460.00 mm.
30: Width Min Limit 0.00 ~ 655.35 [mm] $❈
This sets the minimum conveyor width value. The standard setting is
050.00 mm.
40: LMS Flag Off: On $#
This sets whether the unit will be used as a normal or HELPS compatible
machine.
Off: Not compatible
On: Compatible
The standard setting is "Off."
Version 5.0 4 – 24
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
41: Cell Status Unit: Active: Passive $#
This is valid only for HELPS-compatible machines. This sets cell status.
Unit: Unit cell
Active: Active cell
Passive: Passive cell
The standard setting is "Unit."
42: Change Over Mode 0 ~ 200 $#
This is valid only for HELPS-compatible machines. The standard setting
is 0.
43: Auto Start No: Yes $#
This is valid only for HELPS-compatible machines. It sets the start-up
method after changeover has finished.
No: Machine waits for [START] button to be pressed after changeover
is finished.
Yes: Automatic start.
The standard setting is "No."
44: Backup Plate Check No: Yes $#
On HELPS-compatible machines, this determines whether a backup plate
check will be done during changeover.
No: No backup plate changeover check.
Yes: Backup plate changeover check.
The standard setting is "No."
45: Command Line Status RS232C: LAN $❈
This sets the mode of transmission with LMS.
RS232C: Use RS232C
LAN: Use LAN
ETHERNET: Use Ethernet
The standard setting is "RS232C."
46: Command Line Port 0 ~ 30 $#
On HELPS-compatible machines, use the command line to set the RS232C
ports that will be used.
0: Command line will not be used.
1 - 8: Port numbers.
The standard setting is 0.
4 – 25Version 5.0
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
47: ID Station Type S_type: A_type $❈
On HELPS-compatible machines, sets the location of the ID station.
S_type: The ID station is in the machine.
A_type: The ID station is outside the machine.
The standard setting is "A_type."
48: Buzzer warning On: Off $#
On HELPS-compatible machines, this sets whether or not a buzzer sounds
during changeover operator prompts.
On: Buzzer will sound.
Off: Buzzer will not sound.
The standard setting is "On."
49: Process Timer 1 ~ 120000 [msec] $#
On HELPS-compatible machines, this sets the protocol timer value. The
standard setting is 10000 msec.
50: Reader Type 0 ~ 9 $#
On HELPS-compatible machines, when using a bar code reader, this sets
the type of code reader.
0: Bar code reader
1: Pattern code reader
Other: Bar code reader
The standard setting is 0.
51: Code Reader Timer 1 ~ 120000 [msec] $#
This sets the amount of time allowed for a bar code reader to read a board
type code. The standard setting is 10000 [msec].
52: Code Reader Retry 0 ~ 10 $#
This sets the number of times a code reader will read a board again in case
of a misreading the first time. The standard setting is 0.
53: Reader1 Port No. 0 ~ 30 $#
This is valid only for HELPS-compatible machines. Sets the four channel
port number for code reader 1 (top surface).
0: Not used
1 ~ 30: Connector number of the four channel communication board.
The standard setting is 0.
Version 5.0 4 – 26