Chapter 2 Details of Proper DataPart 4
7: Yellow_Flash 0000 0000 0000 0000 #
This sets the conditions under which the yellow light on the signal tower
will flash (input as a 16 bit binary mask pattern). The standard setting is
0010 0000 0001 0010.
8: Blue_Flash 0000 0000 0000 0000 #
This sets the conditions under which the blue light on the signal tower will
flash (input as a 16 bit binary mask pattern). The standard setting is
0000 1000 1100 0001.
Signal Tower Setting Method
Fuji uses the following standards for signal tower operation.
Automatic operation.........................................Blue (Green) Light
Loader operating...............................................Blue (Green) Light
Waiting for PCB.................................................Blue (Green) Flash
Waiting for NEXT..............................................Blue (Green) Flash
Out of parts soon...............................................Blue (Green) Light
..............................................................................Yellow Light
Out of parts: machine stopped........................Yellow Flash
Abnormal occurrence: machine stopped.......Red Flash
Statistical Error Alarm......................................Blue (Green) Light
..............................................................................Yellow Flash
In changeover: operator called .......................Yellow Flash
Vision process error ..........................................Red Light
Machine waiting................................................Blue (Green) Flash
In changeover ....................................................Blue (Green) Flash
Production complete: machine stopped........Yellow Flash
Version 5.0 4 – 20
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
The bit map and the corresponding display is shown below.
Display Bit map Hexadecimal
Reserved 1000 0000 0000 0000 0x8000
Reserved 0100 0000 0000 0000 0x4000
Production complete: machine stopped 0010 0000 0000 0000 0x2000
Reserved 0001 0000 0000 0000 0x1000
In changeover 0000 1000 0000 0000 0x800
Vision process error 0000 0100 0000 0000 0x400
Automatic operation 0000 0010 0000 0000 0x200
Loader operating 0000 0001 0000 0000 0x100
Waiting for PCB 0000 0000 1000 0000 0x80
Waiting for NEXT 0000 0000 0100 0000 0x40
Out of parts soon 0000 0000 0010 0000 0x 20
Out of parts: machine stopped 0000 0000 0001 0000 0x10
Abnormal occurrence: machine stopped 0000 0000 0000 1000 0x8
Statistical Error Alarm 0000 0000 0000 0100 0x4
In changeover: operator called 0000 0000 0000 0010 0x2
Machine waiting 0000 0000 0000 0001 0x1
Example: This is the Fuji standard signal tower blue flash setting
Machine waiting 0000 0000 0000 0001
Waiting for NEXT 0000 0000 0100 0000
Waiting for PCB 0000 0000 1000 0000
In changeover +0000 1000 0000 0000
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Total 0000 1000 1100 0001
The user may set his own standards in this manner.
9: User_Define A 0000 0000 0000 0000 $#
This sets whether or not a buzzer sounds when a defined signal tower lamp
if lit (input as a 16 bit binary mask pattern). It is entered in the same way as
shown in the example above.
4 – 21Version 5.0
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
11: Machine_Status A 0000 0000 0000 0000
This sets special mode parameters (input as a 16 bit binary mask pattern)
that are common to every machine. Change this command to a mode
which is easy to use.
When the Mark Editor Mode is set, the Mark Editor screen will
automatically display when a fiducial mark read error occurs (Mark Editor
Mode).
Also, it is possible to set so that parts consumption report by nozzles will be
sent to the MCS. This mode is available only for MCS-compatible versions.
Note that because development mode settings are being used for machine
development, there is no guarantee that they will work properly.
The standard setting is 0000 0000 0000 0000.
12: Machine_Status B 0000 0000 0000 0000 #
This sets special mode parameters (input as a 16 bit binary mask pattern)
that are common to every machine. Ordinarily this is set to 0.
Change this command to a mode which is easy to use.
When the Nozzle Skip function is set, a nozzle determined as faulty by
nozzle center measurement will automatically be skipped.
When the XY Table Acceleration/Deceleration Reduce Mode is set, it is
possible to lengthen the acceleration or deceleration time for a completed
board returning to the loading position.
Note that because development mode settings are being used for machine
development, there is no guarantee that they will work properly.
The standard setting is 0000 0000 0000 0000.
Special mode
- Development mode
- XY table acceleration
/deceleration reduce mode
- Nozzle skip function
Bit map
1000 0000 0000 0000
0000 0000 0000 0010
0000 0000 0000 0001
Hexa-
decimal
8000H
4H
1H
Applicable
versions
V1.60 and later
T1.31 and later
Special mode
- Development mode
- Development mode
- Parts consumption
mode by nozzles
(Prod. information)
- Mark Editor
Bit map
1000 0000 0000 0000
0100 0000 0000 0000
0000 0000 0000 0010
0000 0000 0000 0001
Hexadecimal
8000H
4000H
2H
1H
Applicable versions
T1.41 and later
T1.60 and later
Version 5.0 4 – 22